Dynacord DRM 4000 owner manual HOW to Install Extensions

Page 29

INTERNAL SETTINGS

9.3 HOW TO INSTALL EXTENSIONS

9.3.1 How to install the Input Transformer (NRS 90233, EDP-No. 121 682)

Contents NRS 90233:

1 x Input Transformer DCN340955

Installation Instructions NRS 90233:

1.Turn off the power of the DRM 4000 and open the cover plate as described before.

2.For installation of the transformer you first have to remove the printed board assembly 80478 (MAIN BOARD). Start with removing the EQ-board 82228.1 by loosening its three locking-screws and tipping the small board over to the rear. Now, loosen all screws of the printed board assembly 80478 (15 screws on the rear panel and 3 screws on the front panel, which lock the sockets in place, 7 screws and 3 bolts on the printed board assembly itself). Also loosen the two locking screws of the front panel on the bottom plate of the appliance. Remove the potentiometer-caps from the 8 channel controls and the 2 master controls by pulling them off to the front. Detach the front panel. If an interface-board has previously been installed, remove it temporarily. After slightly lifting the front of the printed board assembly 80478, pull it to the front of the appliance so that the connectors are free of the rear panel. Now, you are able to remove the printed board assembly 80478 so that it is accessible for installing the transformer.

3.Remove the two resistors of the corresponding input channel (MIC/LINE 1: R1A / R2A, MIC/LINE 2:

R1B / R2B, MIC/LINE 3: R1C / R2C, MIC/LINE 4: R1D / R2D).

4.Using a suction pump, clean the holes for installing the transformer (9 holes per transformer) as well as the holes of the previously removed resistors from soldering tin.

5.Insert the transformer into the prepared holes (position T1A for MIC/LINE 1, position T1B for MIC/LINE 2, position T1C for MIC/LINE 3 and position T1D for MIC/LINE 4)

6.Solder the contacts of the corresponding transformer to the printed board assembly (9 soldering points per transformer).

7.Reinsert all printed board assemblies and reattach the front panel following the opposite manner of their removal. Make sure to fit all connectors and LED’s into the according holes in the front and rear panel. Tighten all locking-screws. Reinsert the interface-board, if you have previously removed it.

8.Re-install the cover plate as described above.

9-4

Image 29 Contents
DRM For US, Canada and Japan only Safety Component has to be Replaced with Original Part onlyContents Characteristics Introduction DRM 4000 CharacteristicsIntroduction Field of ApplicationUnpacking and Warranty Controls and Connections Controls and Connections12, POWER-switch Ducking indicators a / BTone Control LO / HI Control AUX18, Direct OUT 16, Control27, +24V-switch 26, PAD-switch20, Send output 21, MIX in inputQuick Start Uick StartInstallation and Connections Installation and ConnectionsGeneral Notes Input Assignment 1 MIC/LINE inputsOutput Assignment 4.3.1 Master outputs AUX and MIX in inputsSend outputs Direct OutputsExternal VCA-Control Control InputsControl Inputs Level Settings Power-On OperationLevel Adjustment for MIC/LINE-inputs Initial OperationLevel Adjustment for AUX-inputs Special Features of the DRM Special Features of the DRMUsing Ducking Control Limiter OperationUsing The Unit Together With The DPM Software Editor DRM Installation NotesSoftware Editor DRM System RequirementsMenus And The Toolbar File Menu Software Description 7.4.1 GeneralView Menu Basic ConfigurationCommunication Menu About MenuMIC/LINE-inputs Name and CommentAux-inputs OutputsPriority Test Online Control / StatusControl Inputs View Status N Figuring the DRM Configuring the DRMBasic Configuration Internal Configuration Possibilities Internal SettingsInternal Settings / Extensions Low Cut Filter AUX Sensitivity Selection Limiter SettingsHow to install the Input Transformer NRS 90233, EDP-No HOW to Install ExtensionsHow to install the Output Transformer NRS 90227, EDP-No How to install Interface-Boards Peci F I C a T IO N S SpecificationsSpecifications Specific a Tions User ConfigurationSpecifica Tions Block diagram 10.4 RS-232 Interface Programmer’s Instructions Switching Contacts Via SoftwareREMOTE/PRIO value Online-Access to all ParametersDimensions Garantie Warranty