CONTROLS AND CONNECTIONS

2.2 Rear Panel

14, 24 V power supply

These two 6.3mm flat-connectors are utilized to supply the DRM 4000 with an operating voltage of 24 V DC. Whenever incorporating the DRM 4000 in an intercom system, using the system’s already existing supply voltage of 24 V is recommended. For stand-alone operation use the optionally available mains adapter (NRS 90257). Make sure to mind the correct polarity (+ = +24V, - = Ground) when connecting the power supply.

15, REMOTE INTERFACE port

This port allows retrofitting an optional serial interface (RS-232 or RS-485). For further detail, please refer to chapter 9.3 “How To Install Extensions”.

16, CONTROL IN

These control inputs provide access to eight programmable internal states, including: signal routing, ducking control (priority function), level settings, mute, etc. Connecting it to ground activates a control input. The configuration is factory pre-set for using the DRM 4000 in a multitude of applications. Utilizing a serial interface (optionally available) allows configuring the functions of the eight control inputs via PC-software according to your personal needs. These setting can be saved in the DRM 4000. For details on the pin-assignment and an example of how connection is established, please refer to chapter 4.4.1.

17, External VCA-control

These control contacts allow the connection of two external potentiometers for remotely controlling the volume settings of Master A and B. The VCA’s of the two master outputs A or B are controlled by DC-voltage. Please, keep in mind that audio levels of eventually prioritized microphones (Priority Override is enabled) are not attenuated by VCA-control. For details on the pin-assignment and an example of how connection is established, please refer to chapter 4.4.2.

18, DIRECT OUT

Each of the eight input channels (MIC/LINE single-channel and AUX two-channel) has an individual direct output. It is possible to internally assign the direct outputs to PRE (the signal path is split prior to the tone control and volume setting section) or POST (the signal path is split after the tone control and volume setting section). For details on the pin-assignment, please refer to chapter 4.3.3.

19, Master Outputs OUT A / B

These are the two balanced XLR-type outputs of the DRM 4000. They can be used as L/R-stereo or as two separate monaural outputs, depending on the configuration of the DRM4000.

2-3

Image 8 Contents
DRM Safety Component has to be Replaced with Original Part only For US, Canada and Japan onlyContents Introduction DRM 4000 Characteristics CharacteristicsIntroduction Field of ApplicationUnpacking and Warranty Controls and Connections Controls and ConnectionsDucking indicators a / B 12, POWER-switchTone Control LO / HI Control AUX16, Control 18, Direct OUT26, PAD-switch 27, +24V-switch20, Send output 21, MIX in inputUick Start Quick StartInstallation and Connections Installation and ConnectionsGeneral Notes Input Assignment 1 MIC/LINE inputsAUX and MIX in inputs Output Assignment 4.3.1 Master outputsSend outputs Direct OutputsExternal VCA-Control Control InputsControl Inputs Power-On Operation Level SettingsLevel Adjustment for MIC/LINE-inputs Initial OperationLevel Adjustment for AUX-inputs Special Features of the DRM Special Features of the DRMUsing Ducking Control Limiter OperationUsing The Unit Together With The DPM Installation Notes Software Editor DRMSoftware Editor DRM System RequirementsSoftware Description 7.4.1 General Menus And The Toolbar File MenuBasic Configuration View MenuCommunication Menu About MenuName and Comment MIC/LINE-inputsAux-inputs OutputsPriority Test Online Control / StatusControl Inputs View Status Configuring the DRM N Figuring the DRMBasic Configuration Internal Configuration Possibilities Internal SettingsInternal Settings / Extensions Low Cut Filter Limiter Settings AUX Sensitivity SelectionHOW to Install Extensions How to install the Input Transformer NRS 90233, EDP-NoHow to install the Output Transformer NRS 90227, EDP-No How to install Interface-Boards Peci F I C a T IO N S SpecificationsSpecifications User Configuration Specific a TionsSpecifica Tions Block diagram Switching Contacts Via Software 10.4 RS-232 Interface Programmer’s InstructionsOnline-Access to all Parameters REMOTE/PRIO valueDimensions Warranty Garantie