Dynacord DRM 4000 Internal Settings / Extensions, Internal Configuration Possibilities

Page 26

INTERNAL SETTINGS

9. INTERNAL SETTINGS / EXTENSIONS

CAUTION: The following instructions for installing and setting extensions are meat for the qualified service technician only. In case you are not qualified for carrying out the described tasks, please contact your dealer for further assistance.

Do not perform any maintenance that is not explained in this owner’s manual. Otherwise you will risk injury through shock hazard. Leave all servicing and maintenance to the experienced and qualified service technician.

To be able to make changes to internal settings or retrofit extension you have to open the DRM 4000. To do so, please proceed as follows:

1.Switch off the power of the DRM 4000 and disconnect the mains cord.

2.Loosen the screws of the cover plate (2 frontal screws on the top plate, 2 rear screws on the top plate) and remove the cover by lifting the rear and pulling the entire plate off in the rear direction.

3.When changing settings and/or installing extensions, painstakingly follow the provided instructions.

4.Reattach the cover plate by fitting its front while slightly lifting the rear. Now, slide the cover plate to the front, so that it slides approximately 7 mm under the front panel. While lowering the cover plate’s rear, make sure that the frontal lug fixes the small, upright indicators printed board assembly in place while the cover plate’s rear notch fixes the small, upright printed board assembly in the area of the MIC/LINE-inputs in place. Afterwards, tighten the four cover plate locking screws again.

9.1 Internal Configuration Possibilities

Several internal configurations of the DRM 4000 have to be carried out inside of the enclosure - either by jumper setting or via Cut&Solder-bridges on the main-PCB. The following table provides an overview of the internal configuration possibilities and corresponding factory settings.

Funktion

 

 

 

 

 

Settings

Factory Settings

Low Cut Filter (MIC/LINE 1 - 4)

 

 

 

 

 

ON / OFF

ON

DIRECT OUTPUTS (Kanäle 1 - 8)

 

 

 

PRE / POST

POST

AUX Empfindlichkeit (AUX 1 - 4)

 

 

 

-6 / +4 dBu

+4 dBu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9-1

Image 26 Contents
DRM Safety Component has to be Replaced with Original Part only For US, Canada and Japan onlyContents Introduction Introduction DRM 4000 CharacteristicsCharacteristics Field of ApplicationUnpacking and Warranty Controls and Connections Controls and ConnectionsTone Control LO / HI Ducking indicators a / B12, POWER-switch Control AUX16, Control 18, Direct OUT20, Send output 26, PAD-switch27, +24V-switch 21, MIX in inputUick Start Quick StartGeneral Notes Installation and ConnectionsInstallation and Connections Input Assignment 1 MIC/LINE inputsSend outputs AUX and MIX in inputsOutput Assignment 4.3.1 Master outputs Direct OutputsExternal VCA-Control Control InputsControl Inputs Level Adjustment for MIC/LINE-inputs Power-On OperationLevel Settings Initial OperationLevel Adjustment for AUX-inputs Using Ducking Control Special Features of the DRMSpecial Features of the DRM Limiter OperationUsing The Unit Together With The DPM Software Editor DRM Installation NotesSoftware Editor DRM System RequirementsSoftware Description 7.4.1 General Menus And The Toolbar File MenuCommunication Menu Basic ConfigurationView Menu About MenuAux-inputs Name and CommentMIC/LINE-inputs OutputsPriority Test Online Control / StatusControl Inputs View Status Configuring the DRM N Figuring the DRMBasic Configuration Internal Configuration Possibilities Internal SettingsInternal Settings / Extensions Low Cut Filter Limiter Settings AUX Sensitivity SelectionHOW to Install Extensions How to install the Input Transformer NRS 90233, EDP-NoHow to install the Output Transformer NRS 90227, EDP-No How to install Interface-Boards Peci F I C a T IO N S SpecificationsSpecifications User Configuration Specific a TionsSpecifica Tions Block diagram Switching Contacts Via Software 10.4 RS-232 Interface Programmer’s InstructionsOnline-Access to all Parameters REMOTE/PRIO valueDimensions Warranty Garantie