Enhancements related to operation
Shift Lock on/off ([SHIFT]+[YES])
It is now possible to control the Shift Lock switch (which temporarily keeps [SHIFT] activated while it is not actually pressed) without opening the System Parameter window
1.Press [PLAY (DISPLAY)].
2.Hold down [SHIFT] and press [YES].
3.Thereafter, each time you hold down [SHIFT] and press [YES], Shift Lock can be toggled on/off.
MEMO
When Shift Lock is OFF, the SHIFT indicator will light only while you continue pressing [SHIFT]. When Shift Lock is ON, the SHIFT indicator will light, or go out each time you press [SHIFT]. [SHIFT] is active when the SHIFT indicator is lit.
Removing direct current offset from the mix bus
Direct current offset on the mix bus can be removed. For example, in some cases the level meters of a device (mixer etc.) connected to the output of the
1.Press [PLAY (DISPLAY)].
2.Hold down [SHIFT] and press [F5 (SYSTEM)].
3.Make sure that the System menu is displayed. If not, press [F6 (EXIT)].
4.Press [PAGE] so that [F2] indicates “GLOBL,” and then press [F2 (GLOBL)].
5.Use [][][ ][ ] to move the cursor to “DC Cut,” and use the TIME/VALUE dial to make the setting.
If “DC Cut” is not shown, press [F2 (Prm2)], and use the TIME/VALUE dial to make the setting.
fig.6-31_75
DC Cut
When this is turned “On,” any direct current offset on the mix bus will be removed before output.
6.Press [PLAY (DISPLAY)].
38