Meyer Sound LX-300 manual Removal and Installation of Modules, Module Removal, Module Installation

Page 20

Removal and Installation of Modules

Removal and Installation of Modules

All modules must be installed to a valid slot position. Incorrect assignment of modules to slots may result in hardware failure or poor performance, although the modules themselves will not be damaged.

Caution

Circuit card assemblies contain Electrostatic Discharge Sensitive (ESDS) components. Take appropriate precautions when handling expansion modules.

Module Removal

1.Power off the LX-300.

2.Label all cables attached to the module.

3.Disconnect all cables from the module.

4.Using a #2 Phillips screwdriver, completely loosen the module mounting captive machine screws. There are two or four mounting captive machine screws, located at the top and bottom edges of the module. The captive machine screws are permanently attached to the module.

5.Using gentle force, grasping the left-most pair of captive machine screws, pull the module from the frame. If the module does not slide out easily, stop and find what is blocking it. Do not pry the module out!

6.Immediately place the module in an anti-static bag.

Important

Do not pull the module using the right-hand pair of mounting captive machine screws. They are not attached to the module. Pulling on them will distort the panel.

Module Installation

1.Power off the LX-300.

2.Check the slot assignments. Modules will not function if assigned to an incompatible slot. Remove the blank slot cover, if used.

3.Ensure the module engages the top and bottom rails. Modules that are not correctly aligned with the rails will not install correctly. Using gentle force, slide the module firmly into place. Do not force the module!

4.Secure the mounting captive machine screws firmly and equally. Finger-tighten only: do not over-tighten. Tighten the left-most captive machine screws first.

Important

Push the module using the left-most mounting captive machine screws. Do not apply force to the right-most captive machine screws: they are not attached to the module and pushing them will distort the panel.

5.Attach cables, according to labeling. Ensure cables are snapped or fastened firmly into place.

6.If installing the LX-DSP, LX-EXP, or LX-VRA processor modules, set the Frame ID.

7.Power on the LX-300.

20

Image 20
Contents Hardware Reference Matrix3 Audio Show Control SystemPage Page Page Table of Contents Page LX-300 Start Up Routine OverviewPost Failure Power-On Self TestHardware Initialization If System Flash Memory is Empty System Firmware StartupIf System Flash Memory Contains Firmware EtherTracks Startup Subsystem Initialization FailureFirmware Updates Firmware Installation IssuesBefore You Begin Wait Until CompleteFirmware Update Procedures Disable LX-300 Auto StartUpgrading a Matrix3 System Running CueStation Download Firmware Files Connect CueStation to the LX-300Upgrading a System from Eprom Mode Upgrading a System Running CueStation Open CueStation 4, and select Network Server localhostPage NV RAM Settings Special DSP ID CodesLX-ELC Flash System FlashMessage Meaning Erasing Flash MemoryID Action Page Matrix3 Repair Procedures Replacement of Power FuseSkills Required Required Tools and ComponentsModule Removal Removal and Installation of ModulesModule Installation Restoring Processor Modules Page LX-300 Maintenance Inspection and Maintenance ProcedureRecommended Schedule Inspection ScheduleOperational Testing Hardware Specifications LX-300 SpecificationsLX-300 Chassis Slot Assignments Slot Cards Allowed in Slot * exclusivelyPower Requirements Component Specifications LX-ML8 Mic/Line Analog Audio InputLX-Ai8 Analog Audio Input Pin-outs LX-ML8 Balanced Female XLRRatio Pin-outs LX-Ai8 Balanced Female XLRDigital Signal Level ADA Scale InputsPin-out LX-Ao8 balanced male XLR LX-Ao8 Analog Audio OutputOutput Load Impedance Analog Output Signal Level ADA Scale OutputsPin-out LED Status IndicatorLX-CBR CobraNet Audio Interface LX-AES Component Specifications Pin Name Signal Use LX-DSP System ProcessorDigital Logic Inputs Special DSP ID NumbersLX-EXP Expansion DSP LX-VRA Vras DSPLX-ELC Ethernet/Wild Tracks Pin-outs LX-LNK InterconnectTransmission Range Component Specifications LX-COS Comm/Sync PortsPin-outs Nine-pin Male RS232 Serial Port DTE Nine-pin Female RS422 Serial Port DTEXLR Male Smpte Out Five-pin DIN Female Midi OutXLR Female Smpte Page LX-300 Error Codes Frame Status Error CodesNumber of Green-Red Blinks Cause of Error Error Code ExplanationFrame Status Error Messages CueStation Log Window Messages Page Shipping Address AppendixReturns Policy