CueStation Log Window Messages
Repeated occurrence of an error indicates a fault with the associated expansion module ("DMA0" corresponds to an Analog Audio Input module; "DMA1" to a CobraNet module).
CueStation Log Window Messages
CueStation's Log window reports a number of errors from the Matrix3 system. These can be helpful in diagnosing the root cause of a failure. The messages relevant to booting an
Error Code | Explanation |
M3 E1.5.0, Built on yy/mm/dd, at hh:mm:ss | No Flash program detected. |
DMEM memory usage exceeded. |
|
Total Dynamix points exceeded x | Matrix exceeds DSP capacity. |
DSP Usage has reached limit. Halting processing. Please ADSIR_InterruptsHaveBackedUp
Corrupt audio detected. Muting audio for 1 second. | ADSIR_BadSampleDetected |
Unmuting audio. |
|
HSB Packet error detected | INITMAIN_HSB_Packet_Error |
FLASH ReadFile got wrong CRC for file x, wanted y, got Flash program memory error z
FLASH ReadRawFile got wrong CRC for file x, wanted y, got z
FPGA still not done after 4mSeconds waiting | Various FPGA programming errors |
FPGA Length |
|
FPGA program error. Byte x, bit x TotalBits x |
|
FPGA 'DONE' not active at end of write. |
|
ETRX: Cannot allocate memory | Various EtherTracks Errors |
ETRX: Cannot read et_boot.bin (x) |
|
ETRX: Corrupted
Read Again: [0x]=0x, should be 0x
ETRX: Could not read et_linux.bin (x, 0x) Trying a second time
ETRX: CRC failed. ET=0x Should be=0x. #P=x LAST[0x]
ETRX: # Packets not right. ET=0x Should be=0x. #P=x LAST[0x]
45