Meyer Sound LX-300 manual CueStation Log Window Messages

Page 45

CueStation Log Window Messages

Repeated occurrence of an error indicates a fault with the associated expansion module ("DMA0" corresponds to an Analog Audio Input module; "DMA1" to a CobraNet module).

CueStation Log Window Messages

CueStation's Log window reports a number of errors from the Matrix3 system. These can be helpful in diagnosing the root cause of a failure. The messages relevant to booting an LX-300 are:

Error Code

Explanation

M3 E1.5.0, Built on yy/mm/dd, at hh:mm:ss

No Flash program detected.

DMEM memory usage exceeded.

 

Total Dynamix points exceeded x

Matrix exceeds DSP capacity.

DSP Usage has reached limit. Halting processing. Please ADSIR_InterruptsHaveBackedUp re-send configuration.

Corrupt audio detected. Muting audio for 1 second.

ADSIR_BadSampleDetected

Unmuting audio.

 

HSB Packet error detected

INITMAIN_HSB_Packet_Error

FLASH ReadFile got wrong CRC for file x, wanted y, got Flash program memory error z

FLASH ReadRawFile got wrong CRC for file x, wanted y, got z

FPGA still not done after 4mSeconds waiting

Various FPGA programming errors

FPGA Length Mis-Match

 

FPGA program error. Byte x, bit x TotalBits x

 

FPGA 'DONE' not active at end of write.

 

ETRX: Cannot allocate memory

Various EtherTracks Errors

ETRX: Cannot read et_boot.bin (x)

 

ETRX: Corrupted DualPort->HSB transfer. [0x]=0x, should be 0x

Read Again: [0x]=0x, should be 0x

ETRX: Could not read et_linux.bin (x, 0x) Trying a second time

ETRX: CRC failed. ET=0x Should be=0x. #P=x LAST[0x]

ETRX: # Packets not right. ET=0x Should be=0x. #P=x LAST[0x]

45

Image 45
Contents Matrix3 Audio Show Control System Hardware ReferencePage Page Page Table of Contents Page Overview LX-300 Start Up RoutinePower-On Self Test Hardware InitializationPost Failure System Firmware Startup If System Flash Memory Contains FirmwareIf System Flash Memory is Empty Subsystem Initialization Failure EtherTracks StartupFirmware Installation Issues Firmware UpdatesBefore You Begin Wait Until CompleteDisable LX-300 Auto Start Firmware Update ProceduresUpgrading a Matrix3 System Running CueStation Download Firmware Files Connect CueStation to the LX-300Upgrading a System from Eprom Mode Open CueStation 4, and select Network Server localhost Upgrading a System Running CueStationPage Special DSP ID Codes NV RAM SettingsLX-ELC Flash System FlashErasing Flash Memory ID ActionMessage Meaning Page Replacement of Power Fuse Matrix3 Repair ProceduresSkills Required Required Tools and ComponentsRemoval and Installation of Modules Module InstallationModule Removal Restoring Processor Modules Page Inspection and Maintenance Procedure LX-300 MaintenanceRecommended Schedule Inspection ScheduleOperational Testing LX-300 Specifications Hardware SpecificationsLX-300 Chassis Slot Assignments Slot Cards Allowed in Slot * exclusivelyPower Requirements LX-ML8 Mic/Line Analog Audio Input Component SpecificationsPin-outs LX-ML8 Balanced Female XLR LX-Ai8 Analog Audio InputRatio Pin-outs LX-Ai8 Balanced Female XLRADA Scale Inputs Digital Signal LevelLX-Ao8 Analog Audio Output Output Load ImpedancePin-out LX-Ao8 balanced male XLR ADA Scale Outputs Analog Output Signal LevelLED Status Indicator LX-CBR CobraNet Audio InterfacePin-out LX-AES Component Specifications LX-DSP System Processor Pin Name Signal UseDigital Logic Inputs Special DSP ID NumbersLX-VRA Vras DSP LX-EXP Expansion DSPLX-ELC Ethernet/Wild Tracks LX-LNK Interconnect Transmission RangePin-outs Component Specifications Ports LX-COS Comm/SyncPin-outs Nine-pin Male RS232 Serial Port DTE Nine-pin Female RS422 Serial Port DTEFive-pin DIN Female Midi Out XLR Female SmpteXLR Male Smpte Out Page Frame Status Error Codes LX-300 Error CodesNumber of Green-Red Blinks Cause of Error Error Code ExplanationFrame Status Error Messages CueStation Log Window Messages Page Appendix Returns PolicyShipping Address