Component Specifications

Table 3. LX-300 IEC AC Power Connector

Pin Name

1 Hot

2 Ground

3 Neutral

Component Specifications

LX-ML8 Mic/Line Analog Audio Input

The LX-ML8 provides eight balanced XLR audio inputs with software-controlled microphone and line level gain settings. The analog audio is converted to 24bit/48kHz digital data for processing by the LX-DSP. Up to two analog input cards (for a total of sixteen input channels) can be used in a single LX-300. The cards must be installed in Slots A or B.

Channels

Eight analog mic/line inputs.

Frequency Response

20Hz —20kHz (+/- 0.5dB)

Sampling

24bit/48kHz

Dynamic Range

109 dB (+26dBu, 20 kHz BW)

THD+N

<0.001% (+26dBu, 20-20kHz)

EIN

-125dBu (22kHz BW, max gain, Rs=150 ohms)

Crosstalk

-110dB (20-20kHz, +26dBu, channel-channel)

CMRR

-60dB (20-20kHz, -57dBu)

Input Load Impedance

9.2k ohms (balanced line-to-line)

Gain Settings for Full Scale

+26dBu, +16dBu to -57dBu in 1dB steps

Phantom Power

+48VDC at 10mA, switched per channel

27

Image 27
Contents Matrix3 Audio Show Control System Hardware ReferencePage Page Page Table of Contents Page Overview LX-300 Start Up RoutinePower-On Self Test Hardware InitializationPost Failure System Firmware Startup If System Flash Memory Contains FirmwareIf System Flash Memory is Empty Subsystem Initialization Failure EtherTracks StartupWait Until Complete Firmware UpdatesFirmware Installation Issues Before You BeginDownload Firmware Files Connect CueStation to the LX-300 Firmware Update ProceduresDisable LX-300 Auto Start Upgrading a Matrix3 System Running CueStationUpgrading a System from Eprom Mode Open CueStation 4, and select Network Server localhost Upgrading a System Running CueStationPage System Flash NV RAM SettingsSpecial DSP ID Codes LX-ELC FlashErasing Flash Memory ID ActionMessage Meaning Page Required Tools and Components Matrix3 Repair ProceduresReplacement of Power Fuse Skills RequiredRemoval and Installation of Modules Module InstallationModule Removal Restoring Processor Modules Page Inspection Schedule LX-300 MaintenanceInspection and Maintenance Procedure Recommended ScheduleOperational Testing Slot Cards Allowed in Slot * exclusively Hardware SpecificationsLX-300 Specifications LX-300 Chassis Slot AssignmentsPower Requirements LX-ML8 Mic/Line Analog Audio Input Component SpecificationsPin-outs LX-Ai8 Balanced Female XLR LX-Ai8 Analog Audio InputPin-outs LX-ML8 Balanced Female XLR RatioADA Scale Inputs Digital Signal LevelLX-Ao8 Analog Audio Output Output Load ImpedancePin-out LX-Ao8 balanced male XLR ADA Scale Outputs Analog Output Signal LevelLED Status Indicator LX-CBR CobraNet Audio InterfacePin-out LX-AES Component Specifications Special DSP ID Numbers Pin Name Signal UseLX-DSP System Processor Digital Logic InputsLX-VRA Vras DSP LX-EXP Expansion DSPLX-ELC Ethernet/Wild Tracks LX-LNK Interconnect Transmission RangePin-outs Component Specifications Nine-pin Female RS422 Serial Port DTE LX-COS Comm/SyncPorts Pin-outs Nine-pin Male RS232 Serial Port DTEFive-pin DIN Female Midi Out XLR Female SmpteXLR Male Smpte Out Page Error Code Explanation LX-300 Error CodesFrame Status Error Codes Number of Green-Red Blinks Cause of ErrorFrame Status Error Messages CueStation Log Window Messages Page Appendix Returns PolicyShipping Address