Meyer Sound LX-300 manual Upgrading a System Running CueStation

Page 14

Firmware Update Procedures

This assumes that the firmware in the LX-DSP and LX-ELC has been completely erased. You must have an LX- COS Communication / Synchronization module in your system since the EPROM in the LX-DSP module is only able to connect to a serial port.

Important

If there is an LX-EXP module in the system with an ID set higher than 32, it will not accept firmware while in EPROM mode. Change the ID to a number less than 32 before beginning the firmware upload.

For newer computers without an RS-232 serial port, we have used the Keyspan USB to Serial adapter (USA-19QW). Other adapters have been used successfully.

Even if the LX-ELC still has valid firmware, you will not be able to connect to the DSP. It is best to start with a known good state. If you are in EPROM mode, the Frame Status display on the LX-300 will show "-EP-" and the Watchdog LED will flash red and green.

1.Connect the serial port of your laptop to a serial port on the LX-COS. For this example we will use the RS-232 port (Port C). The communication rate is 38.4kbs, 1 stop bit and no parity.

2.In the Mixer Configuration window, go to the Configuration menu and select Upload Firmware...

3.Select the appropriate firmware file(s) and click Open to upload the files.

4.Watch the Frame Status display for "File Good", there will not be any completion messages in the log. The EtherTracks firmware usually takes between 15 and 20 minutes to upload over serial.

Note

You can also verify that the file transfer has finished by looking at the "Frame Control" LED on the LX-300. It displays serial activity. If is dark then CueStation has finished sending the file. Please be aware that any serial activity will light the Frame Control LED, so if there is a CueMixer compact Matrix3 control surface or other device connected to any of the serial ports they can cause the Frame Control LED to light independently of the file transfer.

Upgrading a System Running CueStation 3

This information is only needed if you are upgrading an older Matrix3 system running BeOS and CueStation 3.

CueStation 4 requires an LX-ELC EtherTracks module with 128MB of memory. Systems with older LX-ELC modules must upgrade the 64MB SODIMM to a Meyer Sound-approved 128MB SODIMM.

Important

There are two different physical memory mappings of the 128MB SODIMM. Only a two bank type setup as 8MB by 16b will work with the LX-ELC module. The minimum speed is PC-100. Please use only memory modules provided by Meyer Sound.

CueStation 4 client can not directly connect to a LX-300 running version 3 firmware. To make a connection you must use VirtualLX.

1.Open CueStation 4, and select Network > Server > localhost (127.0.0.1).

2.In VirtualLX, enable Show Details. Select the HSB Simulator tab.

3.At the bottom of the window there is a drop down menu and a data entry box. In the data entry box, enter the IP address of the LX-ELC module. This is the IP address that the LX-300 displays on power up in the Frame Status display.

14

Image 14
Contents Hardware Reference Matrix3 Audio Show Control SystemPage Page Page Table of Contents Page LX-300 Start Up Routine OverviewPost Failure Power-On Self TestHardware Initialization If System Flash Memory is Empty System Firmware StartupIf System Flash Memory Contains Firmware EtherTracks Startup Subsystem Initialization FailureBefore You Begin Firmware UpdatesFirmware Installation Issues Wait Until CompleteUpgrading a Matrix3 System Running CueStation Firmware Update ProceduresDisable LX-300 Auto Start Download Firmware Files Connect CueStation to the LX-300Upgrading a System from Eprom Mode Upgrading a System Running CueStation Open CueStation 4, and select Network Server localhostPage LX-ELC Flash NV RAM SettingsSpecial DSP ID Codes System FlashMessage Meaning Erasing Flash MemoryID Action Page Skills Required Matrix3 Repair ProceduresReplacement of Power Fuse Required Tools and ComponentsModule Removal Removal and Installation of ModulesModule Installation Restoring Processor Modules Page Recommended Schedule LX-300 MaintenanceInspection and Maintenance Procedure Inspection ScheduleOperational Testing LX-300 Chassis Slot Assignments Hardware SpecificationsLX-300 Specifications Slot Cards Allowed in Slot * exclusivelyPower Requirements Component Specifications LX-ML8 Mic/Line Analog Audio InputRatio LX-Ai8 Analog Audio InputPin-outs LX-ML8 Balanced Female XLR Pin-outs LX-Ai8 Balanced Female XLRDigital Signal Level ADA Scale InputsPin-out LX-Ao8 balanced male XLR LX-Ao8 Analog Audio OutputOutput Load Impedance Analog Output Signal Level ADA Scale OutputsPin-out LED Status IndicatorLX-CBR CobraNet Audio Interface LX-AES Component Specifications Digital Logic Inputs Pin Name Signal UseLX-DSP System Processor Special DSP ID NumbersLX-EXP Expansion DSP LX-VRA Vras DSPLX-ELC Ethernet/Wild Tracks Pin-outs LX-LNK InterconnectTransmission Range Component Specifications Pin-outs Nine-pin Male RS232 Serial Port DTE LX-COS Comm/SyncPorts Nine-pin Female RS422 Serial Port DTEXLR Male Smpte Out Five-pin DIN Female Midi OutXLR Female Smpte Page Number of Green-Red Blinks Cause of Error LX-300 Error CodesFrame Status Error Codes Error Code ExplanationFrame Status Error Messages CueStation Log Window Messages Page Shipping Address AppendixReturns Policy