Meyer Sound LX-300 manual LX-DSP System Processor, Digital Logic Inputs, Special DSP ID Numbers

Page 35

Component Specifications

LX-DSP System Processor

Performs matrix mixing automation and control, using the TI-TMS320C6701 Digital Signal Processor. This DSP card also holds 32MB SDRAM and 8MB Flash memory, allowing stand-alone operation once programmed with an automation cue list. The DSP is also interfaced to four relay contact outputs, four digital sensor inputs and two analogue sensor inputs for control and reading of external devices.

Channels

Maximum 160/512 audio I/O channels

Dynamic Range

192dB

Digital Logic Inputs

LX-DSP cards with serial numbers 0000–0688 require an external pull-up resistor to use the Digital Logic Inputs. Connect a 1/4W 2K2 resistor between the Digital Logic Input terminal and the +5V reference voltage. One resistor is required for each Digital Logic Input.

Special DSP ID Numbers

The ID switch on an LX-DSP module can be set to force the LX-300 to erase the flash memory. This is not required in normal operation. See Special DSP ID Codes (p. 16) for more information.

LX-DSP Pin-outs: LX-DSP Sensor I/O Terminal Block

Pin

Name

Signal

Use

1

+5V ref

+5V

Reference voltage

2

ADC1

0-5V

Analog sensor input

3

ADC2

0-5V

Analog sensor input

4

D1

-TTL (active low with

internal Digital logic input

5

D2

2K2 pull-up resistor)

 

 

 

6

D3

 

 

7

D4

 

 

8

GND ref

GND

Reference ground

9

R1

500mA@48V max

Relay N/O dry contact

10

11 R2

12

13 R3

14

15 R4

16

35

Image 35
Contents Matrix3 Audio Show Control System Hardware ReferencePage Page Page Table of Contents Page Overview LX-300 Start Up RoutinePost Failure Power-On Self TestHardware Initialization If System Flash Memory is Empty System Firmware StartupIf System Flash Memory Contains Firmware Subsystem Initialization Failure EtherTracks StartupWait Until Complete Firmware UpdatesFirmware Installation Issues Before You BeginDownload Firmware Files Connect CueStation to the LX-300 Firmware Update ProceduresDisable LX-300 Auto Start Upgrading a Matrix3 System Running CueStationUpgrading a System from Eprom Mode Open CueStation 4, and select Network Server localhost Upgrading a System Running CueStationPage System Flash NV RAM SettingsSpecial DSP ID Codes LX-ELC FlashMessage Meaning Erasing Flash MemoryID Action Page Required Tools and Components Matrix3 Repair ProceduresReplacement of Power Fuse Skills RequiredModule Removal Removal and Installation of ModulesModule Installation Restoring Processor Modules Page Inspection Schedule LX-300 MaintenanceInspection and Maintenance Procedure Recommended ScheduleOperational Testing Slot Cards Allowed in Slot * exclusively Hardware SpecificationsLX-300 Specifications LX-300 Chassis Slot AssignmentsPower Requirements LX-ML8 Mic/Line Analog Audio Input Component SpecificationsPin-outs LX-Ai8 Balanced Female XLR LX-Ai8 Analog Audio InputPin-outs LX-ML8 Balanced Female XLR RatioADA Scale Inputs Digital Signal LevelPin-out LX-Ao8 balanced male XLR LX-Ao8 Analog Audio OutputOutput Load Impedance ADA Scale Outputs Analog Output Signal LevelPin-out LED Status IndicatorLX-CBR CobraNet Audio Interface LX-AES Component Specifications Special DSP ID Numbers Pin Name Signal UseLX-DSP System Processor Digital Logic InputsLX-VRA Vras DSP LX-EXP Expansion DSPLX-ELC Ethernet/Wild Tracks Pin-outs LX-LNK InterconnectTransmission Range Component Specifications Nine-pin Female RS422 Serial Port DTE LX-COS Comm/SyncPorts Pin-outs Nine-pin Male RS232 Serial Port DTEXLR Male Smpte Out Five-pin DIN Female Midi OutXLR Female Smpte Page Error Code Explanation LX-300 Error CodesFrame Status Error Codes Number of Green-Red Blinks Cause of ErrorFrame Status Error Messages CueStation Log Window Messages Page Shipping Address AppendixReturns Policy