Meyer Sound manual LX-300 Error Codes, Status LED Blink Codes, Frame Status Error Codes

Page 43

LX-300 Error Codes

Status LED Blink Codes

43

Frame Status Error Codes

43

Frame Status Error Messages

44

CueStation Log Window Messages

45

The LX-300 reports the identifiable errors through one or a combination of methods: Status LED blinking, Frame Status error code reports, Frame Status error messages, and CueStation Log window messages.

Identifying the error and its probable root cause helps you choose an appropriate troubleshooting strategy.

Status LED Blink Codes

There are several system failure errors that make it impossible to display an error code directly. For these errors, the Status LED will repeatedly blink the error code, with a pause between each cycle. The number of green-red blinks corresponds to the error code.

Number of Green-Red Blinks

Cause of Error

1

Bad HSB File

2

Bad Serial File

3

Memory Allocation Error

4

File Size Mismatch

5

Bitfile Bad Program

6

Main FPGA Error

7

ISR Initialization Failure

These seven errors indicate a failure of the LX-DSP processor module.

Rebooting may resolve the error. The LX-300 should be treated as suspect.

Repeated failure indicates the LX-DSP processor module is non-functional. Replace the LX-DSP with a known-good module. Return the non-working module to Meyer Sound for repairs.

Multiple LX-DSP failures indicate a problem with the LX-300 itself. Replace the LX-300 with a known-good LX-300. You may re-use the modules from the non-working LX-300, but they should be treated as suspect until proved good (they may have been damaged by the non-working LX-300.) Return the non-working LX-300 to Meyer Sound for repairs.

Multiple LX-300 failures indicate a problem with the facility power system. This is a situation beyond the scope of this manual. Facility power problems may result in non-warrantable damage to your LX-300s.

Please consult the Removal and Installation of Modules (p. 20) instructions for details on safe LX-300 expansion dis/assembly.

Frame Status Error Codes

Most errors are shown as an error code on the Frame Status display.

Error Code

Explanation

IE12

Could not update Link FPGA program

IE13

Successfully returned from Flash program loading init-

 

main.cpp

43

Image 43
Contents Matrix3 Audio Show Control System Hardware ReferencePage Page Page Table of Contents Page Overview LX-300 Start Up RoutineHardware Initialization Power-On Self TestPost Failure If System Flash Memory Contains Firmware System Firmware StartupIf System Flash Memory is Empty Subsystem Initialization Failure EtherTracks StartupWait Until Complete Firmware UpdatesFirmware Installation Issues Before You BeginDownload Firmware Files Connect CueStation to the LX-300 Firmware Update ProceduresDisable LX-300 Auto Start Upgrading a Matrix3 System Running CueStationUpgrading a System from Eprom Mode Open CueStation 4, and select Network Server localhost Upgrading a System Running CueStationPage System Flash NV RAM SettingsSpecial DSP ID Codes LX-ELC FlashID Action Erasing Flash MemoryMessage Meaning Page Required Tools and Components Matrix3 Repair ProceduresReplacement of Power Fuse Skills RequiredModule Installation Removal and Installation of ModulesModule Removal Restoring Processor Modules Page Inspection Schedule LX-300 MaintenanceInspection and Maintenance Procedure Recommended ScheduleOperational Testing Slot Cards Allowed in Slot * exclusively Hardware SpecificationsLX-300 Specifications LX-300 Chassis Slot AssignmentsPower Requirements LX-ML8 Mic/Line Analog Audio Input Component SpecificationsPin-outs LX-Ai8 Balanced Female XLR LX-Ai8 Analog Audio InputPin-outs LX-ML8 Balanced Female XLR RatioADA Scale Inputs Digital Signal LevelOutput Load Impedance LX-Ao8 Analog Audio OutputPin-out LX-Ao8 balanced male XLR ADA Scale Outputs Analog Output Signal LevelLX-CBR CobraNet Audio Interface LED Status IndicatorPin-out LX-AES Component Specifications Special DSP ID Numbers Pin Name Signal UseLX-DSP System Processor Digital Logic InputsLX-VRA Vras DSP LX-EXP Expansion DSPLX-ELC Ethernet/Wild Tracks Transmission Range LX-LNK InterconnectPin-outs Component Specifications Nine-pin Female RS422 Serial Port DTE LX-COS Comm/SyncPorts Pin-outs Nine-pin Male RS232 Serial Port DTEXLR Female Smpte Five-pin DIN Female Midi OutXLR Male Smpte Out Page Error Code Explanation LX-300 Error CodesFrame Status Error Codes Number of Green-Red Blinks Cause of ErrorFrame Status Error Messages CueStation Log Window Messages Page Returns Policy AppendixShipping Address