Altinex MT109-102 manual Ver, CnS

Page 10

MULTI-TASKER™

The Group ID is a number representing a group of cards defined with the [WR] command. When using the Group ID, all cards in the group will perform the given instruction.

Changing the position of a card will significantly affect the commands recorded on software definitions or third party control systems.

The Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to zero, each command may be used without Ui. Use the command [SETU0], as explained in the MT100-100 User’s Guide.

Example:

[VERC3]: For Unit ID Zero

[VERC3Ui]: For Unit ID other than Zero

[VERC3]: Equivalent to [VERC3U0]

1.[VER]

This command displays the software version and card type for the MT109-102card.

Command Format: [VERCnUi]

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

An MT109-102card is in slot #4. Send the command [VERC4], and the Multi-Tasker™ Enclosure will return the following feedback:

MT109-102 690-0133-008

MT109-102 = the card model

690-0133-008 = the software version

2.[C]

This command receives the status of the card.

Command Format: [CnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

400-0343-003

9

Example:

There is one MT109-102card in slot #4. Sending the command [C4] to the Multi-Tasker™ will display feedback similar to the following:

In1Vol=16/16

In2Vol=16/16

In3Vol=16/16

OutVol=16/16

Bass =08/16

Treble=08/16

Loudness:OFF

The status shows the input volume settings, in this case 16 out of 16, the output volume, the bass and treble levels and that the loudness feature is turned off.

If there is no card in slot #4, sending the [C4] command will not return any feedback.

3.[CnS]

This command saves the card volume settings. This configuration will be restored after the system is reset or powered off then on.

Command Format: [CnSUi]

Cn = Card ID (n = # from 1 to max slots)

S = save configuration

Ui = Unit ID (i = # from 0 to 9)

Example:

There is an MT109-102in slot #4. All volume levels are set to the maximum of 16. The bass and treble levels are set to 08. Save the settings of the card by sending the command [C4S]. The feedback will be as follows:

In1Vol=16/16

In2Vol=16/16

In3Vol=16/16

OutVol=16/16

Bass =08/16

Treble=08/16

Loudness:OFF

Card Status Saved

9

Image 10
Contents MT109-102 Troubleshooting Guide General Precautions / Safety WarningsCleaning FCC / CE NoticeTechnical Specifications About Your MT109-102Description of MT109-102 Application Diagram Diagram 1 Typical SetupDiagram 2 Internal View SW5 Diagram 3 Switch Positions INPUT1 INPUT2 INPUT3 Line OutputSW1 OFF SW2 SW3 SW4 SW6Operation Installing Your MT109-102Description of Commands RS-232 ControlVER CnS?Ui ?CnUiSTA Selo SELImSelb VLIxAm SeltVloa VlbaCLR Volume Ramping FeatureLOD1 RUPRST RDNRDN=xx RampTest Card ID CommandsRamptime = 16 Seconds Memory is GoodSIDnCi RSISIDn SID+36. WR RSNHelp RMCClrg RMG39. RD CLMSelo STASeli SelbMenu Command Definitions Menu ModeUsing Menu Mode SUB Menus Menu TypesMain Menu 4 MT109-102 MenusSave VolumeMT109-102 Expanded Menus Control this Card ClearSet Output Volume Menu Mode ExamplesSet Input 3 Volume Select this Card for controlLED is not on Troubleshooting GuideNo Sound Sound Distortion Limited WARRANTY/RETURN PolicyAltinex Policy Sound Level is LOW