BACK PANEL FEATURES

10

11

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

13

8

8.INPUT SECTION

The ICASeries comes standard with plugable input connectors and individual channel rotary attenuators. Connections at the input connector permit the audio signal ground to be connected or lifted from the chassis ground.

9.OUTPUT BARRIER STRIP

A barrier strip is provided for connection of loudspeakers with bare wire or spade lug connectors. This barrier strip can accommodate up to two 10-gauge wires per terminal.

10.IEC POWER CONNECTOR

A standard IEC power connector is located at the upper left corner of the amplifier rear panel.

An AC mains cord having an appropriate AC plug for the intended operating voltage is included.

NOTE: FOR UK ONLY

If the colors of the wires in the mains lead of this unit do not correspond with the colored markings identifying the terminals in your plug, proceed as follows: (1) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E, the earth symbol, colored green, or colored green and yellow. (2) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black. (3). The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red.

11.CIRCUIT BREAKER

A resettable, protective AC circuit breaker is located at the upper left of the amplifier back

panel. If the breaker has tripped, push it back in to return the amplifier to operating condition. If the breaker continues to trip, the amplifier needs servicing. Do not continue to reset the breaker because severe internal damage and safety hazards could occur!

12.SEQUENTIAL TURN-ON CONNECTOR

The ICASeries comes standard with remote-controllable sequential turn on enabled by setting the front power switch to STANDBY. The amplifier is activated by applying a voltage between 12 to 24 volts DC to the rear-mounted, 4-pin plugable terminal, and connecting the ENABLE terminal to the 24 V DC+ terminal. When no voltage is present or the ENABLE connection is opened, the amplifier will switch off. Other ICA Series amplifiers can be “daisy chained” by connecting all 24 V DC+ terminals together, all COMMON terminals together, and

6

Image 6
Contents A S E R I E S Page Table of Contents Introduction Installation and MountingBasic Setup UnpackingPower LED Front Panel FeaturesPosition AC Power Switch Signal LEDSequential TURN-ON Connector Back Panel Features Input SectionIEC Power Connector Output Barrier StripOperation Signal Mode Configuration Stereo Mode Connection Diagram Parallel Mode DiagramProtection Features Thermal Protection Sequential TURN-ON / TURN-OFFFADE-IN Protection Short CircuitWire Gauge Chart ICA 600 Specifications Rated Power 2 X 4 ohms Slew Rate CoolingICA 1200 Specifications Gross Weight 51.4 lbs .3 kg Net WeightICA 2400 Specifications ICA 400V Specifications THD two channels driven ICAICA 800V Specifications ICA 2400V Specifications Instalación Y Montura IntroducciónDesempacar Instalación BásicaInstalador Para Rack Interruptor DE Poder AC Power DE Tres PosicionesCaracterísticas DEL Panel Frontal LED DE PoderCaracterísticas DEL Panel Trasero Sección DE EntradaConectores DE Salida DE Para Cables Operación Diagrama DE Modo Estéreo Diagrama DE Modo Paralelo Conexión DE Tierra Diagrama DE Modo PuenteadoConexiones DE Salida DE Bocinas Características DE ProtecciónCorto Circuito Protección DE FADE-INProtección Térmica Protección DE Voltaje DE CDFicha DE Medidas DE Cables Especificaciones del ICA Razón de Slew Topología Especificaciones del ICA 400V Poder Medido dos canales THD Distorsión Total Armónica dos canales Installation DeballageMise EN Route Pattes DE Fixation Rack LED DE SignalPanneau Avant Interrupteur 3-POSITIONS D’ALIMENTATIONSorties Panneau ArriereEntrees Connecteur D’ALIMENTATION IECRefroidissement Configuration DU Signal D’ENTREEAlimentation Electrique Emissions ThermiquesStereo Mode Connection Diagram Parallel Mode Diagram Connexions HAUTS-PARLEUR Masse DU SignalSystemes DE Protection Clip LimiteurProtection Thermale Mise EN ROUTE/ARRET SequentielsProtection DE Mise EN Route Protection DE Court CircuitStranded Power ICA 600 Specifications ICA 1200 Specifications ICA 2400 Specifications ICA 400V Specifications ICA 800V Specifications Input Cmrr Rated Power one channel Einbau UND Anschluss EinleitungAuspacken Erste SchritteVorderseite POWER-LEDSIGNAL-LED Montagezubehör FÜR DEN RACK-EINBAURückseite LFC-LEDPROTECT-LED EingangsmodulBedienung Wärmeentwicklung BetriebsartenSTEREO-BETRIEB Brückenbetrieb SignalerdungPARALLEL-BETRIEB LautsprecheranschlussEinschaltverzögerung CLIP-LIMITERLastfehlerkorrektur ÜberhitzungsschutzVerkabelung Sequentielle Ein/Ausschalt-Funktion Wire Gauge Chart ICA 600 Specifications ICA 1200 Specifications ICA 2400 Specifications ICA 400V Specifications ICA 800V Specifications ICA 2400V Specifications Page Peavey Electronics Corporation Limited Warranty Important Safety Instructions 80304800