Peavey ICA Series, ICA 600, ICA 800V, ICA 400V, ICA 2400V, ICA 1200 manual Operation

Page 7

connecting the ENABLE OUT to the ENABLE IN of the next amplifier. A mating connector is shipped with the amplifier.

13.FAN GRILL

A continuously variable-speed DC fan supplies cool air into the amplifier. Do not block this

intake! The fan operates only when the amplifier heat sinks require cooling.

OPERATION

AC MAINS CIRCUIT SIZE REQUIREMENTS

Power requirements for ICAamplifiers are rated at “idle”, 1/8 power (“typical” music conditions), 1/3 power, and maximum rated power. The maximum power current draw rating

is limited by the amplifier’s circuit breaker. Consult the specification sheet for the current that each amplifier will demand. AC mains voltage must be the same as that indicated on the back of the amplifier. Damage caused by connecting the amplifier to improper AC voltage is not covered by any warranty. NOTE: Always turn off and disconnect the amplifier from the mains voltage before making audio connections. As an extra precaution, have the input attenuators turned down during initial power up.

COOLING REQUIREMENTS

ICA Series amplifiers use a forced-air cooling system to maintain a low, even operating temperature. Cooling air is drawn by a continuously variable-speed fan mounted on the back

panel, and exhausts through slots on the front panel. The fan will remain inactive until internal operating temperature rises above 45º C (113º F). Make sure there is enough space around the back of the amplifier to allow air to enter. NOTE: If the amplifier is rack mounted, do not use doors or covers on the front or back without pressurizing the back of the rack. Whatever type of rack you are using, make sure that heated air can escape freely, and that there is no resistance to the intake of cool air through the back grill. Intake and exhaust air must flow without resistance.

HIBERNATION

All ICA Series amps feature Hibernation circuitry. Current draw and thermal emissions are at a minimum when the absence of input signal is sensed for more than a minute. Once signal is present, Hibernation instantly restores the amplifier to normal. Current draw specifications while Hibernation is active are included in specifications under Idle Current Draw.

THERMAL EMISSIONS

The system installer or designer should specify system cooling needs. Refer to the specifications at the back of this manual for specific thermal emissions figures.

INPUT CONNECTIONS

The input connector accepts balanced and unbalanced audio signals. For use with an unbalanced source, tie the inverting (-) input to ground by installing a jumper to the signal ground connection. If the inverting input is left floating, a 6 dB loss in gain will result.

7

Image 7
Contents A S E R I E S Page Table of Contents Unpacking Installation and MountingBasic Setup IntroductionSignal LED Front Panel FeaturesPosition AC Power Switch Power LEDOutput Barrier Strip Back Panel Features Input SectionIEC Power Connector Sequential TURN-ON ConnectorOperation Stereo Mode Connection Diagram Parallel Mode Diagram Signal Mode ConfigurationProtection Features Short Circuit Sequential TURN-ON / TURN-OFFFADE-IN Protection Thermal ProtectionWire Gauge Chart Rated Power 2 X 4 ohms Slew Rate Cooling ICA 600 SpecificationsGross Weight 51.4 lbs .3 kg Net Weight ICA 1200 SpecificationsICA 2400 Specifications THD two channels driven ICA ICA 400V SpecificationsICA 800V Specifications ICA 2400V Specifications Instalación Básica IntroducciónDesempacar Instalación Y MonturaLED DE Poder Interruptor DE Poder AC Power DE Tres PosicionesCaracterísticas DEL Panel Frontal Instalador Para RackSección DE Entrada Características DEL Panel TraseroConectores DE Salida DE Para Cables Operación Diagrama DE Modo Estéreo Diagrama DE Modo Paralelo Características DE Protección Diagrama DE Modo PuenteadoConexiones DE Salida DE Bocinas Conexión DE TierraProtección DE Voltaje DE CD Protección DE FADE-INProtección Térmica Corto CircuitoFicha DE Medidas DE Cables Especificaciones del ICA Razón de Slew Topología Especificaciones del ICA 400V Poder Medido dos canales THD Distorsión Total Armónica dos canales Deballage InstallationMise EN Route Interrupteur 3-POSITIONS D’ALIMENTATION LED DE SignalPanneau Avant Pattes DE Fixation RackConnecteur D’ALIMENTATION IEC Panneau ArriereEntrees SortiesEmissions Thermiques Configuration DU Signal D’ENTREEAlimentation Electrique RefroidissementStereo Mode Connection Diagram Parallel Mode Diagram Clip Limiteur Masse DU SignalSystemes DE Protection Connexions HAUTS-PARLEURProtection DE Court Circuit Mise EN ROUTE/ARRET SequentielsProtection DE Mise EN Route Protection ThermaleStranded Power ICA 600 Specifications ICA 1200 Specifications ICA 2400 Specifications ICA 400V Specifications ICA 800V Specifications Input Cmrr Rated Power one channel Erste Schritte EinleitungAuspacken Einbau UND AnschlussMontagezubehör FÜR DEN RACK-EINBAU POWER-LEDSIGNAL-LED VorderseiteEingangsmodul LFC-LEDPROTECT-LED RückseiteBedienung Betriebsarten WärmeentwicklungSTEREO-BETRIEB Lautsprecheranschluss SignalerdungPARALLEL-BETRIEB BrückenbetriebÜberhitzungsschutz CLIP-LIMITERLastfehlerkorrektur EinschaltverzögerungVerkabelung Sequentielle Ein/Ausschalt-Funktion Wire Gauge Chart ICA 600 Specifications ICA 1200 Specifications ICA 2400 Specifications ICA 400V Specifications ICA 800V Specifications ICA 2400V Specifications Page Peavey Electronics Corporation Limited Warranty Important Safety Instructions 80304800