USER INSTRUCTIONS

1.general

1.1Installation and servicing must only be carried out by a competent person.

1.2In all correspondence, please quote the appliance type and serial number, which can be found on the data badge adjacent to the control knob.

1.3Ensure that curtains are not positioned above the fire, and that there is a 300mm minimum clearance between the sides of the fire and any curtains.

1.4This product is guaranteed for 12 months from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco dealer. Please consult with your local Gazco dealer if you have any questions. In all correspondence always quote the Model Number and Serial Number.

1.5Parts of this appliance become hot during normal use. It is therefore recommended that a suitable fire guard be used for protection of young children and the infirm.

2.LIGHTING THE FIRE

2.1Locate the control valve on the appliance. There are two control knobs on the valve, the right hand knob controls the pilot ignition and the left hand knob controls the main burner.

2.2If your appliance has already been upgraded to battery remote control, please refer to the instructions provided with the upgrade to operate the remote control. The following instructions will work for either situation.

1

AR0914

2.3Ensure that the left-hand control knob is pointing to off .

2.4Ensure that the right hand control knob is pointing to off .

2.5Press in the right hand control knob and rotate it anti-clockwise until a click is heard (keep pressing in) and the knob is pointing

to pilot ( ). The pilot should now light. If the pilot has not

lit,

repeat the procedure until it does.

2.6Keep the control knob pressed for 10 seconds and then release it, the pilot should stay alight. If the pilot goes out, repeat the procedures until it does.

2.7If the pilot will not light after repeated attempts, contact the retailer or installer from whom the appliance was purchased.

2.8Turn the right hand control to point to main burner (). The appliance can now be controlled using the left hand control knob.

2.9Turn the left hand control knob to point to low fire (), the main burner will light on low. The burner can now be controlled between low and high settings. Turn the control knob anti clockwise increase the flame height and clockwise to decrease the flame height.

THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES.

3.TURNING THE FIRE OFF

3.1To turn the fire off, locate the control valve, turn the left- hand control knob until it points to off (). The main burner will go out leaving the pilot burning.

3.2To turn the pilot off, locate the control valve, turn the right hand control knob until it points to off (), the pilot will go out.

4.LIGHTING THE FIRE WITH A MATCH

If the pilot does not ignite as described in Section 2, please consult your GAZCO dealer to rectify the problem. However, the appliance may be lit as a temporary measure using the following procedure:

4.1Press in the right hand control knob and rotate it anti- clockwise until a click is heard (keep pressing in) and the knob is pointing to pilot (), apply a lighted match to the pilot hood, see diagram 2.

2

AR1164

4.2When the pilot is alight, extinguish the match and continue to depress for 5 to 10 seconds.

4.3The fire may now be controlled as previously described.

5.UPGRADING YOUR FIRE

5.1Your fire is fitted with a control valve that can easily be upgraded to battery powered remote control. This upgrade

4

Image 4
Contents Logic Hotbox & Convector Fire Contents FLUE CHECK APPLIANCE COMMISSIONING CHECKLISTGAS CHECK User Instructions Lighting the FireTurning the Fire OFF Lighting the Fire with a MatchCleaning the Fire Arrangement of Fuel BED ComponentsCoal Layout Front ROW Coal Layout Using Flat Fire Fronts Installation Details Oxygen Depletion SensorFlame Failure Device 10. ‘RUNNING IN’Installation Instructions Technical SpecificationMinimum Debris Collection Flue and Chimney Requirements Site RequirementsAppliance Location GAS Supply Installation Installation of the Appliance Cable Retention MethodScrew Fixing Method AR1163 AR1160 AR1174 AR1171 Installation / Commissioning CommissioningServicing Servicing InstructionsServicing Requirements Servicing Instructions Fault Finding Charts Fault Finding Charts General Replacing PartsIgnition Lead Gas valve Mag unit Service Records 9th Service 10th Service