INSTALLATION

B)SCREW FIXING METHOD

6.8Alternatively, this appliance can be secured back to the

fire place opening using the screws and rawl plugs provided. Place the firebox centrally in the opening and mark the positions of the 4 fixing holes. Drill the holes and insert the 4 rawl plugs. See diagram 7.

7

AR1158

6.9Offer the firebox into the opening and ensure that the gas supply pipe passes through the rubber seal.

6.10Refit the burner assembly and secure the 6 pozidriv screws. Connect the gas supply to the inlet connection on the burner unit and tighten. It may be necessary to support the inlet connection with another spanner whilst tightening this joint. See diagram 8.

8

AR1175

6.11Turn on the gas supply to the appliance and check for leaks. Light the fire and check all joints on the appliance for leaks.

6.12Remove the sealing screw from the inlet connection and connect a suitable “U” gauge manometer. Light the fire and turn to the maximum position, refer to the data badge and ensure that the running pressure is correct. If the pressure varies significantly from that on the data badge, this may indicate a supply problem and will require immediate attention.

6.13Turn the appliance off, disconnect the “U” gauge and replace the sealing screw. Relight the appliance and check the sealing screw for leaks.

7.ARRANGEMENT OF FUEL BED COMPONENTS

NOTE: CERAMIC PARTS ARE FRAGILE. THE SIDE AND REAR PANELS ARE REVERSIBLE. ONE SIDE IS PLAIN, THE OTHER SIDE IS REEDED. ASK THE CUSTOMER WHICH SIDE IS PREFERRED AT THIS STAGE.

ONLY USE THE CORRECT TYPE AND QUANTITY OF CERAMIC COMPONENTS. POINTS 7.1 TO 7.5 ARE COMMON TO ALL FUEL TYPES AND LAYOUTS.

7.1Position the burner cover gasket on the burner skin ensuring the holes align with the ports. Take care as the front left-hand hole is offset compared to the others.

See diagram 9, arrow A.

9

AR1175

7.2Position the flame baffle centrally on the tray and ensure the stepped lower edge engages against the rear edge of the burner skin. See diagram 10.

10

AR1159

14

Image 14
Contents Logic Hotbox & Convector Fire Contents GAS CHECK APPLIANCE COMMISSIONING CHECKLISTFLUE CHECK Turning the Fire OFF User InstructionsLighting the Fire Lighting the Fire with a MatchCleaning the Fire Arrangement of Fuel BED ComponentsCoal Layout Front ROW Coal Layout Using Flat Fire Fronts Flame Failure Device Installation DetailsOxygen Depletion Sensor 10. ‘RUNNING IN’Installation Instructions Technical SpecificationMinimum Debris Collection Appliance Location Site RequirementsFlue and Chimney Requirements GAS Supply Installation Installation of the Appliance Cable Retention MethodScrew Fixing Method AR1163 AR1160 AR1174 AR1171 Installation / Commissioning CommissioningServicing Requirements Servicing InstructionsServicing Servicing Instructions Fault Finding Charts Fault Finding Charts Ignition Lead Replacing PartsGeneral Gas valve Mag unit Service Records 9th Service 10th Service