Stovax PR0696 manual Mag unit

Page 23

SERVICING INSTRUCTIONS

REPLACING PARTS

5.5Replace in reverse order.

5.6Check all joints for gas leaks, check operation of the thermocouple and ignition lead.

6.mag unit

6.1Remove the fire, refer to section 1.

6.2Under the thermocouple nut. See diagram 11 arrow B.

6.3Undo the mag unit retaining nut at the back of the control valve behind the thermocouple nut.

11

B

AR1177

6.4After removing the retaining nut, the mag unit can be tapped out and a replacement fitted.

6.5Replace the mag unit retaining nut and tighten. Note - this is a gas-tight seal.

6.6Replace the thermocouple and check for gas leaks.

6.7After reassembly, carry out the flame failure functional check as detailed in the flow chart, especially the mag unit drop out time.

7.main injector

7.1Remove the fire, refer to section 1.

7.2With the fire removed, undo the injector compression nut and valve nut (see diagram 12 arrows D and E), pull the pipe clear of the injector body.

12

D

E

AR1177

 

7.3Rotate the injector until it is fully removed.

7.4Replace with the correct replacement injector. When ordering, always state the model, gas type and serial number.

7.5Reassemble and turn the gas supply on, check for any leaks.

8. changing between gas types

The following parts must be changed when converting an appliance from one gas type to another:

Burner assembly

NGA8306

 

LPGAP8306

Data badge

PR0393L

Note: The control valve will be set for the particular appliance and gas type. In all instances, when ordering new parts, be sure to quote the appliance type and serial number.

Use only genuine Gazco replacement parts. Non-standard components will invalidate the guarantee and may be dangerous.

9. spares part lists

 

 

 

CERAMICS

 

 

 

 

FRONT COAL - BLACK

 

CE0400

 

 

 

FRONT COAL - GREY

 

CE0401

 

 

 

FLAME BAFFLE - BLACK

 

CE0402

 

 

 

FLAME BAFFLE - GREY

 

CE0403

 

 

 

BURNER COVER GASKET

 

CE0273

 

 

 

CONVECTOR SIDE LH

 

CE0408

 

 

 

CONVECTOR SIDE RH

 

CE0409

 

 

 

CONVECTOR REAR PANEL

 

CE0410

 

 

 

CONVECTOR TOP PANEL

 

CE0411

 

 

 

HOTBOX SIDE LH

 

CE0404

HOTBOX SIDE RH

 

CE0405

HOTBOX REAR PANEL

 

CE0406

 

 

 

HOTBOX TOP PANEL

 

CE0407

 

 

 

COAL SET

 

CE0412

PEBBLE SET

 

CE0455

 

 

 

NATURAL GAS PARTS

 

 

 

MAIN INJECTOR

 

IN0007

 

 

 

PILOT ASSEMBLY

 

PI0036

 

 

 

GAS VALVE

 

GC0088

 

 

 

LPG PARTS

 

 

 

MAIN INJECTOR

 

IN0025

 

 

 

PILOT ASSEMBLY

 

PI0037

 

 

 

GAS VALVE

 

GC0088

 

 

 

MISCELLANEOUS

 

 

 

IGNITION LEAD

 

GC0090

 

 

 

MAG UNIT

 

GC0092

 

 

 

CONTROL COVER

 

GC0087

 

 

 

UPGRADE KIT

 

8455

 

 

 

23

Image 23
Contents Logic Hotbox & Convector Fire Contents GAS CHECK APPLIANCE COMMISSIONING CHECKLISTFLUE CHECK Lighting the Fire with a Match User InstructionsLighting the Fire Turning the Fire OFFArrangement of Fuel BED Components Cleaning the FireCoal Layout Front ROW Coal Layout Using Flat Fire Fronts 10. ‘RUNNING IN’ Installation DetailsOxygen Depletion Sensor Flame Failure DeviceTechnical Specification Installation InstructionsMinimum Debris Collection Appliance Location Site RequirementsFlue and Chimney Requirements GAS Supply Installation Cable Retention Method Installation of the ApplianceScrew Fixing Method AR1163 AR1160 AR1174 AR1171 Commissioning Installation / CommissioningServicing Requirements Servicing InstructionsServicing Servicing Instructions Fault Finding Charts Fault Finding Charts Ignition Lead Replacing PartsGeneral Gas valve Mag unit 9th Service 10th Service Service Records