Stovax PR0696 manual Installation Instructions, Technical Specification

Page 8

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

Covering the following models

 

 

Hotbox

Convector

 

 

 

8306PBUC

8308PBUC

 

 

 

P80306PBUC

P8308PBUC

 

 

 

8306MCUC

8308MCUC

 

 

 

P8306MCUC

P8308MCUC

 

 

 

 

 

 

 

 

GAS CATEGORY

 

I2H

 

I3+

 

 

 

Natural

 

Butane

 

Propane

 

 

 

 

 

 

 

Gas Type

 

G20

 

G30

 

G31

 

 

 

 

 

 

 

Working Pressure

 

20mb

 

29mb

 

37mb

Gross Input kW

High

6.7

 

6.7

 

6.7

 

Low

3.0

 

3.0

 

3.0

Gas Rate m3/hr

High

0.64

 

0.192

 

0.252

 

Low

0.29

 

0.086

 

0.113

 

 

 

 

 

 

 

Nox Class

 

1

 

1

 

Injector Size

 

400

 

180

 

Aeration Size

 

6 x 15

 

6 x 15 Rear

 

 

 

 

 

 

 

 

 

 

 

23 x 15 Front

 

 

 

 

 

 

 

Min flue size

 

 

 

5" diameter

 

Min flue size - pre cast

 

 

90mm x 183mm (16,500mm2 min)

 

Min flue specification

 

 

 

T260 / N2 / 0 / D / 1

 

Gas Inlet

 

 

 

8mm

 

 

 

 

 

 

 

Weight (Gross

 

 

 

19Kg

 

 

 

 

 

 

 

 

APPLICABLE FRONTS

FRONT

HOTBOX

CONVECTOR

 

 

 

DESIGNIO

8251MA, 8251IR, 8251GP

8251MA, 8251IR, 8251GP

 

 

 

EVOLUTION

8255MB, 8255BS

8257MB, 8257BS

HOLYROOD

8391

8391

 

8397

8397

 

8150

8150

INFINITI

8249BS

8249BS

PROGRESS

8253MA, 8253IR

8253MA, 8253IR

 

 

 

RICHMOND

N/A

8678

 

 

 

SPANISH

8382, 8385

8382, 8385

 

8388, 8153

8388, 8153

VICTORIAN CONVECTOR

N/A

4262, 4263

 

 

 

ART NOUVEAU CONVECTOR

N/A

4264, 4265

 

 

 

COMBINATION CONVECTOR

N/A

4362. 4363

DIMENSION

8681MB

8681MB

ARTS FRONT

8288MB, 8288HP, 8288P, 8288PBR

8288MB, 8288HP, 8288P, 8288PBR

 

 

 

ARTS FRAME

8284MB, 8284PBR, 8284P, 8284BS

8284MB, 8284PBR, 8284P, 8284BS

 

 

 

8

Image 8
Contents Logic Hotbox & Convector Fire Contents GAS CHECK APPLIANCE COMMISSIONING CHECKLISTFLUE CHECK User Instructions Lighting the FireTurning the Fire OFF Lighting the Fire with a MatchCleaning the Fire Arrangement of Fuel BED ComponentsCoal Layout Front ROW Coal Layout Using Flat Fire Fronts Installation Details Oxygen Depletion SensorFlame Failure Device 10. ‘RUNNING IN’Installation Instructions Technical SpecificationMinimum Debris Collection Appliance Location Site RequirementsFlue and Chimney Requirements GAS Supply Installation Installation of the Appliance Cable Retention MethodScrew Fixing Method AR1163 AR1160 AR1174 AR1171 Installation / Commissioning CommissioningServicing Requirements Servicing InstructionsServicing Servicing Instructions Fault Finding Charts Fault Finding Charts Ignition Lead Replacing PartsGeneral Gas valve Mag unit Service Records 9th Service 10th Service