Enviro C-10100 service manual Blower Diagnosis ALL Models

Page 21

7)BLOWER DIAGNOSIS ALL MODELS

Check to make sure that the fan is plugged in.

Make sure the fan control knob is in the “ON”

position.

Make sure the two wires are connected to the

fan temperature sensor.

Make sure that the two wires are connected to

the blower.

Make sure there are no broken, damaged or

frayed wires.

Make sure that the fan sensor is secure and that

it is not damaged.

Using a supply cord connected to the blower, plug the blower directly into wall outlet.

By pass the fan temperature sensor with a jumper wire.

By pass the fan controller with

a jumper wire.

If the blower does not work,

replace the blower.

If the blower works, replace the fan temperature sensor

If the blower does not work, replace the fan controller.

MAKE SURE THAT THE FAN SENSOR IS AT OPERATING TEMPERATURE BEFORE TESTING THE FAN CONTROLLER.

 

 

 

 

 

 

Sherwood Industries Ltd.

ENVIRO

PAGE 19

 

 

 

 

 

 

Image 21
Contents GAS Fireplace Suggested Tools List for Servicing Table of ContentsSee page 2 Figure 1PILOT will not Light No Spark Ignition System175mm See page 4 Figure Piezo Ignitor OK but Pilot will Still not LightTo remove pilot injector Exploded View S.I.T Pilot AssemblySupply Pressures 50% Turn Down Natural GAS Propane GAS Proper Voltage These Readings should be Constant with no FluctuationChecking Thermocouple forPilot will not Stay LIT T Eurosit Modulating 630 Series Main Burners will not Light See page 8 FigureSee page 6 Figure Main Burners will not Light CON’T Main Burners will not Stay LIT Vented ModelsSee Enviro Sample Direct Vent Chimney Installations ALL Models Enviro Sooting Enviro Vented Models Flame LiftingDo not GO TOO FAR or Unit will Soot See page 5 Figure EnviroDirect Vent Models Blower Diagnosis ALL Models Natural GAS Propane GAS DRILL# Size Orifice Sizing ChartStep by Step Service Instructions Cleaning the Appliance Glossary