Enviro C-10100 service manual Glossary

Page 25

10) GLOSSARY

B-VENTED SYSTEM

A venting system using only approved double wall pipe and approved B-vent components. This system also uses room air for proper venting action through the dilution air inlet mounted on the back of the unit.

CONTINUITY TEST

By using a multimeter set on OHMS, is determined if the circuit is complete, or continuous (no break in the circuit).

DIRECT VENT SYSTEM

A venting system sealed from the structure for both the exhaust gases and fresh air supply.

ELECTRODE (ignition)

Receives spark from the piezo ignitor to light the pilot.

IGNITOR (piezo)

A component used to create an electrical spark to the electrode to light the pilot.

IMPINGEMENT

When flame comes in contact with physical components. Impingement can cause incomplete combustion resulting in carbon monoxide production as well as soot.

MANOMETER

Instrument used to measure gas pressure.

MILLIVOLT

One –one thousands (1/1000) of a volt (.001mV DC)

MULTIMETER

Instrument used to measure Volts. Amps, Ohms, (Volts DC, AC)

ORIFICE

A component that controls gas flow through the burners.

PILOT INJECTOR

A component that directs gas flow through the pilot assembly.

PRESSURE REGULATOR

A device used to maintain downstream gas pressure.

RATING PLATE

A plate in the appliance which shows all certifications and what type of fuel and what the appliance is rated for (example: BTU’s, gas type, serial#, etc.).

SOOTING

Carbon build up produced by incomplete combustion of the fuel being used.

SPILLAGE

When flue products do not properly exit the structure through the venting system.

SPILL SWITCH

A temperature sensitive switch designed to shut the appliance off in the case of improper venting action.

THERMOCOUPLE

A device used to generate power with heat from the pilot, up to 25mV DC.

THERMOPILE

A device used to generate power with heat from the pilot, up to 750mV DC.

VENTURI

Where gas and air are mixed before entering the burner tube.

 

 

 

 

 

 

Sherwood Industries Ltd.

ENVIRO

PAGE 23

 

 

 

 

 

 

Image 25
Contents GAS Fireplace Suggested Tools List for Servicing Table of ContentsSee page 2 Figure 1PILOT will not Light No Spark Ignition System175mm See page 4 Figure Piezo Ignitor OK but Pilot will Still not LightTo remove pilot injector Exploded View S.I.T Pilot AssemblySupply Pressures 50% Turn Down Natural GAS Propane GAS Proper Voltage These Readings should be Constant with no FluctuationChecking Thermocouple forPilot will not Stay LIT T Eurosit Modulating 630 Series See page 8 Figure Main Burners will not LightSee page 6 Figure Main Burners will not Light CON’T Vented Models Main Burners will not Stay LITSee Enviro Sample Direct Vent Chimney Installations ALL Models Enviro Sooting Enviro Vented Models Flame LiftingDo not GO TOO FAR or Unit will Soot See page 5 Figure EnviroDirect Vent Models Blower Diagnosis ALL Models Natural GAS Propane GAS DRILL# Size Orifice Sizing ChartStep by Step Service Instructions Cleaning the Appliance Glossary