Turn the switch to the “ON” position; check the millivolt readings at the thermopile make sure that the readings meet manufacters specifications. Turn the unit “OFF”.

Install a manometer on the inlet side of the gas valve marked (E), re light the appliance make sure that the inlet pressure meets the manufactures specifications.

Shut the unit “OFF” once again and do an outlet (manifold) pressure test. Relight the appliance and make sure the outlet (manifold) pressure is within manufactures specifications.

FINALLY, check to make sure that the unit is venting properly by placing a match in the dilution air outlet or in the draft tube on insert models. If the match is blown out then there is some sort of restriction. Correct if necessary.

CLEANING THE APPLIANCE

Only use a very soft cloth an a non abrasive cleaner, DO NOT use any alcohol’s, mineral spirits, gasoline’s or abrasive cleaners.

When cleaning the glass there could be some stubborn material left on the glass, DO NOT use a scraper or abrasive cleaning agents on the glass because this could scratch the glass which in turn will make he glass weak at the point of the scratch. There is a glass cleaner that is specially designed for gas fireplaces, which can be purchased at your local dealer.

 

 

 

 

 

 

Sherwood Industries Ltd.

ENVIRO

PAGE 22

 

 

 

 

 

 

Image 24
Contents GAS Fireplace Table of Contents Suggested Tools List for Servicing1PILOT will not Light No Spark Ignition System See page 2 Figure175mm Piezo Ignitor OK but Pilot will Still not Light See page 4 FigureExploded View S.I.T Pilot Assembly To remove pilot injectorSupply Pressures 50% Turn Down Natural GAS Propane GAS These Readings should be Constant with no Fluctuation Proper VoltageChecking Thermocouple forPilot will not Stay LIT T Eurosit Modulating 630 Series Main Burners will not Light See page 8 FigureSee page 6 Figure Main Burners will not Light CON’T Main Burners will not Stay LIT Vented ModelsSee Enviro Sample Direct Vent Chimney Installations ALL Models Enviro Sooting Enviro Flame Lifting Vented ModelsDo not GO TOO FAR or Unit will Soot See page 5 Figure EnviroDirect Vent Models Blower Diagnosis ALL Models Orifice Sizing Chart Natural GAS Propane GAS DRILL# SizeStep by Step Service Instructions Cleaning the Appliance Glossary