B) PIEZO IGNITOR OK BUT PILOT WILL STILL NOT LIGHT
Make sure all gas lines have
been connected with no
leaks.
Make sure that the gas is “ON” (NG) Natural gas and (LP) Propane tanks are full.
Make sure the appliance
service valve is in the “ON”
position.
SEE PAGE 4 FIGURE 3.
Test to make sure there is no
air in the gas line.
SEE PAGE 4 FIGURE 3.
Make sure that the valve has
not reset itself.
(All valves have an interlock
safety device.)
Make sure pilot injector is
not clogged.
Correct if necessary, test
for gas leaks in an approved manner.
Correct if necessary.
Turn service valve to the
“ON” position.
Use a match to see if air or gas comes from the pilot assembly.
Wait 60 seconds for the
safety to reset itself.
Clean the pilot injector if
necessary.
|
|
|
|
|
| Sherwood Industries Ltd. | ENVIRO | PAGE 3 |
|
|
|
|
|
|