Enviro C-10100 service manual Piezo Ignitor OK but Pilot will Still not Light, See page 4 Figure

Page 5

B) PIEZO IGNITOR OK BUT PILOT WILL STILL NOT LIGHT

Make sure all gas lines have

been connected with no

leaks.

Make sure that the gas is “ON” (NG) Natural gas and (LP) Propane tanks are full.

Make sure the appliance

service valve is in the “ON”

position.

SEE PAGE 4 FIGURE 3.

Test to make sure there is no

air in the gas line.

SEE PAGE 4 FIGURE 3.

Make sure that the valve has

not reset itself.

(All valves have an interlock

safety device.)

Make sure pilot injector is

not clogged.

Correct if necessary, test

for gas leaks in an approved manner.

Correct if necessary.

Turn service valve to the

“ON” position.

Use a match to see if air or gas comes from the pilot assembly.

Wait 60 seconds for the

safety to reset itself.

Clean the pilot injector if

necessary.

 

 

 

 

 

 

Sherwood Industries Ltd.

ENVIRO

PAGE 3

 

 

 

 

 

 

Image 5
Contents GAS Fireplace Suggested Tools List for Servicing Table of ContentsSee page 2 Figure 1PILOT will not Light No Spark Ignition System175mm See page 4 Figure Piezo Ignitor OK but Pilot will Still not LightTo remove pilot injector Exploded View S.I.T Pilot AssemblySupply Pressures 50% Turn Down Natural GAS Propane GAS Proper Voltage These Readings should be Constant with no FluctuationChecking Thermocouple forPilot will not Stay LIT T Eurosit Modulating 630 Series See page 6 Figure Main Burners will not LightSee page 8 Figure Main Burners will not Light CON’T See Main Burners will not Stay LITVented Models Enviro Sample Direct Vent Chimney Installations ALL Models Enviro Sooting Enviro Vented Models Flame LiftingDo not GO TOO FAR or Unit will Soot See page 5 Figure EnviroDirect Vent Models Blower Diagnosis ALL Models Natural GAS Propane GAS DRILL# Size Orifice Sizing ChartStep by Step Service Instructions Cleaning the Appliance Glossary