1(PILOT WILL NOT LIGHT
NO SPARK
A) IGNITION SYSTEM
Make sure that wires are not broken, frayed and that all connections are tight at both the piezo ignitor and electrode.
Make sure that ceramic on the
electrode is not broken. Carefully try to spin the porcelain.
Make sure a 1/8” (3.175mm) gap is maintained between electrode and pilot hood.
SEE PAGE 2 FIGURE 1.
Make sure the piezo ignitor is
not loose.
Make sure piezo ignitor is working properly. Place a screwdriver next to ignitor, and press ignitor. If it sparks, OK.
Replace with only manufactures parts
IF IT DOES, replace
electrode.
Replace electrode.
Retighten hex nut on back
of the ignitor and make sure bracket is secure on the valve.
IF IT FAILS, replace piezo
ignitor.
|
|
|
|
|
| Sherwood Industries Ltd. | ENVIRO | PAGE 1 |
|
|
|
|
|
|