Enviro C-10100 service manual To remove pilot injector, Exploded View S.I.T Pilot Assembly

Page 6

EXPLODED VIEW S.I.T PILOT ASSEMBLY

To remove pilot injector:

Remove the two screws that hold the pilot assembly to the burner control assembly.

Lift the assembly straight up being careful not to damage any components.

Using a 10 mm wrench undo the securing nut on pilot tubing and pull tubing down to access injector. Being careful not to damage the ceramic spark electrode.

Replace the injector and reinstall the pilot tubing, always to perform a gas leak test before lighting the pilot assembly.

The number on the side of the injector will determine the size. This number is in millimeters.

PILOT HEAD

THERMOPILE

PILOT INJECTOR

SPARK ELECTRODE

THERMOCOUPLE

 

 

 

 

 

 

Sherwood Industries Ltd.

ENVIRO

PAGE 4

 

 

 

 

 

 

Image 6
Contents GAS Fireplace Table of Contents Suggested Tools List for Servicing1PILOT will not Light No Spark Ignition System See page 2 Figure175mm Piezo Ignitor OK but Pilot will Still not Light See page 4 FigureExploded View S.I.T Pilot Assembly To remove pilot injectorSupply Pressures 50% Turn Down Natural GAS Propane GAS Checking These Readings should be Constant with no FluctuationProper Voltage Thermocouple forPilot will not Stay LIT T Eurosit Modulating 630 Series Main Burners will not Light See page 8 FigureSee page 6 Figure Main Burners will not Light CON’T Main Burners will not Stay LIT Vented ModelsSee Enviro Sample Direct Vent Chimney Installations ALL Models Enviro Sooting Enviro Do not GO TOO FAR or Unit will Soot Flame LiftingVented Models See page 5 Figure EnviroDirect Vent Models Blower Diagnosis ALL Models Orifice Sizing Chart Natural GAS Propane GAS DRILL# SizeStep by Step Service Instructions Cleaning the Appliance Glossary