Enviro C-10100 service manual Supply Pressures 50% Turn Down Natural GAS Propane GAS

Page 7

3.5” wc BELOW 0

NO PRESSURE

1.75” wc BELOW 0

3.5” wc ABOVE 0

 

1.75” wc ABOVE 0

INLET GAS PRESSURE

 

OUTLET GAS PRESSURE

7” wc (NG) NATURAL

 

3.5 “ wc (NG) NATURAL

GAS

 

GAS

 

 

SUPPLY PRESSURES

 

 

 

50% TURN DOWN

 

NATURAL GAS

PROPANE GAS

 

 

MAX SUPPLY PRESSURE

7” wc

12” wc

 

 

33% TURN DOWN

MIN SUPPLY PRESSURE

5” wc

11.5” wc

 

 

MAX SUPPLY PRESSURE

7” wc

13” wc

 

 

 

MIN SUPPLY PRESSURE

4.5” wc

10.5” wc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sherwood Industries Ltd.

ENVIRO

PAGE 5

 

 

 

 

 

 

 

Image 7
Contents GAS Fireplace Suggested Tools List for Servicing Table of ContentsSee page 2 Figure 1PILOT will not Light No Spark Ignition System175mm See page 4 Figure Piezo Ignitor OK but Pilot will Still not LightTo remove pilot injector Exploded View S.I.T Pilot AssemblySupply Pressures 50% Turn Down Natural GAS Propane GAS Thermocouple for These Readings should be Constant with no FluctuationProper Voltage CheckingPilot will not Stay LIT T Eurosit Modulating 630 Series See page 8 Figure Main Burners will not LightSee page 6 Figure Main Burners will not Light CON’T Vented Models Main Burners will not Stay LITSee Enviro Sample Direct Vent Chimney Installations ALL Models Enviro Sooting Enviro See page 5 Figure Enviro Flame LiftingVented Models Do not GO TOO FAR or Unit will SootDirect Vent Models Blower Diagnosis ALL Models Natural GAS Propane GAS DRILL# Size Orifice Sizing ChartStep by Step Service Instructions Cleaning the Appliance Glossary