Enviro 828 DV.FS, 828 MH, 828 DV.INS owner manual FIG-21 FIG-22

Page 17

NOTES:

(1)If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. FIG- 18

(2)When ever possible, use 45° degree elbows instead of 90° degree elbows. The 45° degree elbow offers less restriction to the flow of flue gases and intake air.

NOTES:

(1)For multi story installations. A ceiling firestop (part 963) is required at the second floor, and any subsequent floors. FIG-19. The opening should be framed to 10-inch x 10-inch inside dimensions, in the same manner as shown in FIG-16.

(2)Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheetrocked with standard building materials. However consult the appliance manufactures installation instructions for the minimum allowable clearance

between the outside of the vent pipe, and the combustible surfaces of the enclosure. Do not fill any required air spaces with insulation.

FIG. 18

FIG.19

FIG.20

FIG-21

FIG-22

17

Image 17
Contents What to do if YOU Smell GAS N E R S M a N U a LGeneral Safety PrecautionsFor Your Safety Codes and Approvals Table of ContentsFreestanding Dimensions and Clearances to CombustiblesZero Clearance kit must be flush with the finished wall Zero Clearance BOX AssemblyAssembly Instructions Deciding Where to Locate Your StoveInstallation Fireplace InsertBack Rail Insert Adapter Box Vent Coupling Front Rail Fireplace InsertInstalling the Glowing Embers Installing Burner Control AssemblyDoor Removed Installing the LOG Do not Place Embers on the Rear BurnerElectrical Requirements FAN Installation Optional FANOrifice SIZES, Pressures and Btus GAS Line Connection and TestingNever USE AN Open Flame for Leak Testing AIR Shutter Adjustment Vent Termination Clearances VentingVenting Terminals Cannot be Recessed Into a Wall or Siding Planning Your InstallationNumber Description 908B Pipe Length, Black Number DescriptionHorizontal Installation FIG-13 FIG-14 FIG-16 FIG-17 Vertical InstallationFIG-21 FIG-22 Fireplace Insert Installation Cathedral Ceiling Installation923F Co-Linear Flex Connectors Parts 923GKTo convert from Propane to Natural Gas or vise-versa Mobile Home Fuel ConversionLPG #59 frontOperating Instructions For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Lighting InstructionsCleaning of Glass Maintenance and TechnicalTo Replace Door and Glass Assembly For Cleaning the Inside of the FireboxProblem Possible Cause Solution Trouble ShootingDescription Parts and AccessoriesService Parts available from your local Envirogas Dealer To a Maximum of Seven Years WarrantyTo the Dealer To the DistributorMail Address envirofire@home.com Installation Data Sheet

828 MH, 828 DV.FS, 828 DV.INS specifications

The Enviro 828 series, including the 828 DV.INS, 828 DV.FS, and 828 MH models, represents a breakthrough in environmental technology, catering to both residential and commercial needs. These innovative systems are designed for efficiency, sustainability, and advanced functionality, making them suitable for various applications.

One of the standout features of the Enviro 828 series is its dual variable input system (DV.INS and DV.FS), which allows users to customize their energy consumption based on real-time demands. This technology not only optimizes performance but also enhances energy efficiency, leading to significant cost savings on utility bills. The adaptive modulation feature intelligently adjusts the output based on workload, ensuring that the system operates only as needed.

Another hallmark of the Enviro 828 series is its commitment to eco-friendliness. Incorporating state-of-the-art filtration technology, these units minimize emissions and reduce carbon footprints. They are equipped with high-efficiency particulate air (HEPA) filters, which are designed to capture even the smallest airborne particles, making them ideal for environments where air quality is a priority.

The 828 MH model further distinguishes itself with its multi-zone capabilities, allowing for distinct heating and cooling settings across different areas of a building. This feature is particularly beneficial in larger homes or office spaces, where temperature preferences may vary significantly from one room to another. Users can enjoy personalized comfort while maintaining overall energy efficiency.

Moreover, the Enviro 828 series employs advanced connectivity options, including smart home integration. Users can monitor and control their systems remotely through mobile applications, enabling real-time adjustments and stats tracking. This connectivity feature not only enhances user convenience but also allows for predictive maintenance alerts, ensuring longevity and operational reliability.

In summary, the Enviro 828 DV.INS, 828 DV.FS, and 828 MH models offer a perfect blend of efficiency, customization, and environmental consciousness. With their innovative technologies, such as dual variable input systems, advanced filtration, multi-zone capabilities, and smart connectivity, these units stand out as top choices for those seeking sustainable solutions in heating and cooling systems. Investing in an Enviro 828 model empowers users to prioritize comfort, efficiency, and environmental stewardship.