13. MAINTENANCE AND TECHNICAL

Periodically check to ensure that your "Direct Vent" system is clear.

Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with small yellow tips.

OPENING THE DOOR

Caution door is hot when in operation.

1.Open the right hand hinged side flap, which will expose a door fastener. Using a 1/2" wrench, loosen the fastener.

2.Due to the shape of the bay window door. You must also open the left-hand side flap before attempting to open the door.

CLEANING OF GLASS

Do not clean glass when hot

It will be necessary to clean the ceramic glass periodically. During a cold start up, condensation will sometimes form on the glass, this is a normal condition with all gas fireplaces and stoves. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first two weeks of use.

After that, depending upon the amount of use, cleaning should be required no more than two or three times per season.

To clean the door, use a mild glass cleaner and a soft cloth. Abrasive cleaners will damage the glass and gold surfaces. Close door tightly.

TO REPLACE DOOR AND GLASS ASSEMBLY

The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a replacement door assembly including glass must be fitted.

To Replace:

open door fully

Lift door vertically so that hinge pins lift out of hinge receivers.

Return the door assembly to dealer.

Your ENVIROGAS Dealer must replace door and glass assembly as a complete unit.

No substitute materials are allowed.

FOR CLEANING THE INSIDE OF THE FIREBOX

Remove the log carefully from the firebox. Gently remove the embers and place on a piece of paper towel, until ready to replace.

Vacuum the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner.

After carefully replacing the log and embers in their correct positions, and the door has been resealed, re- light the pilot, following the instructions on the attached label.

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE

LUBRICATING THE BLOWER

If installed, the blower should be lubricated every 6 months

1.Turn the unit off and remove the log set.

2.Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift tray out.

3.Remove the 8 screws that hold the blower mounting plate to the back firewall. Use a light lubricating oil on screws before removal.

4.Carefully pull the blower assembly into the firebox, exposing the blower lubricating holes (located on the top of the motor housing on either side of the label). Add 2 drops of SAE 20 oil.

5.If removal of the blower is necessary, disconnect the blower leads from the harness. Remove the blower.

6.To re-install, check mounting plate gasket and reverse steps 1 through 4.

21

Image 21
Contents What to do if YOU Smell GAS N E R S M a N U a LSafety Precautions For Your SafetyGeneral Codes and Approvals Table of ContentsFreestanding Dimensions and Clearances to CombustiblesZero Clearance kit must be flush with the finished wall Zero Clearance BOX AssemblyAssembly Instructions Deciding Where to Locate Your StoveInstallation Fireplace InsertBack Rail Insert Adapter Box Vent Coupling Front Rail Fireplace InsertInstalling the Glowing Embers Installing Burner Control AssemblyDoor Removed Installing the LOG Do not Place Embers on the Rear BurnerElectrical Requirements FAN Installation Optional FANGAS Line Connection and Testing Never USE AN Open Flame for Leak TestingOrifice SIZES, Pressures and Btus AIR Shutter Adjustment Vent Termination Clearances VentingVenting Terminals Cannot be Recessed Into a Wall or Siding Planning Your InstallationNumber Description 908B Pipe Length, Black Number DescriptionHorizontal Installation FIG-13 FIG-14 FIG-16 FIG-17 Vertical InstallationFIG-21 FIG-22 Fireplace Insert Installation Cathedral Ceiling Installation923F Co-Linear Flex Connectors Parts 923GKTo convert from Propane to Natural Gas or vise-versa Mobile Home Fuel ConversionLPG #59 frontOperating Instructions For Your Safety Read Before OperatingWhat to do if YOU Smell GAS Lighting InstructionsCleaning of Glass Maintenance and TechnicalTo Replace Door and Glass Assembly For Cleaning the Inside of the FireboxProblem Possible Cause Solution Trouble ShootingParts and Accessories Service Parts available from your local Envirogas DealerDescription To a Maximum of Seven Years WarrantyTo the Dealer To the DistributorMail Address envirofire@home.com Installation Data Sheet

828 MH, 828 DV.FS, 828 DV.INS specifications

The Enviro 828 series, including the 828 DV.INS, 828 DV.FS, and 828 MH models, represents a breakthrough in environmental technology, catering to both residential and commercial needs. These innovative systems are designed for efficiency, sustainability, and advanced functionality, making them suitable for various applications.

One of the standout features of the Enviro 828 series is its dual variable input system (DV.INS and DV.FS), which allows users to customize their energy consumption based on real-time demands. This technology not only optimizes performance but also enhances energy efficiency, leading to significant cost savings on utility bills. The adaptive modulation feature intelligently adjusts the output based on workload, ensuring that the system operates only as needed.

Another hallmark of the Enviro 828 series is its commitment to eco-friendliness. Incorporating state-of-the-art filtration technology, these units minimize emissions and reduce carbon footprints. They are equipped with high-efficiency particulate air (HEPA) filters, which are designed to capture even the smallest airborne particles, making them ideal for environments where air quality is a priority.

The 828 MH model further distinguishes itself with its multi-zone capabilities, allowing for distinct heating and cooling settings across different areas of a building. This feature is particularly beneficial in larger homes or office spaces, where temperature preferences may vary significantly from one room to another. Users can enjoy personalized comfort while maintaining overall energy efficiency.

Moreover, the Enviro 828 series employs advanced connectivity options, including smart home integration. Users can monitor and control their systems remotely through mobile applications, enabling real-time adjustments and stats tracking. This connectivity feature not only enhances user convenience but also allows for predictive maintenance alerts, ensuring longevity and operational reliability.

In summary, the Enviro 828 DV.INS, 828 DV.FS, and 828 MH models offer a perfect blend of efficiency, customization, and environmental consciousness. With their innovative technologies, such as dual variable input systems, advanced filtration, multi-zone capabilities, and smart connectivity, these units stand out as top choices for those seeking sustainable solutions in heating and cooling systems. Investing in an Enviro 828 model empowers users to prioritize comfort, efficiency, and environmental stewardship.