Hampton Direct U32-NG2, U32-LP2 installation manual Maintenance

Page 19

MAINTENANCE

8)Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile and 1 around the thermocouple, and 1 flowing across the rear of the burner (it does not have to be touching the burner).

Top View of pilot flame

Incorrect flame pattern will have small, proba- bly yellow flames, not coming into proper con- tact with the rear of the burner or thermopile.

Top View of pilot flame

If you have an incorrect flame pattern, contact your FPI dealer for further instructions.

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These compo- nents should be replaced immediately.

2)Remove the Termination Cap, and shine a flashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive conden- sation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fittings. It may be caused by having exces- sive lateral runs, too many elbows, and exterior portions of the system being ex- posed to cold weather.

4)Inspect joints, to verify that no pipe sections or fittings have been disturbed, and conse- quently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s perform- ance which is not covered under warranty.

GLASS GASKET

If the glass gasket requires replacement use glass gasket (Part # 936-265) for the Bay Front and a tadpole gasket for the Flush Front (Part

# 936-155).

GOLD-PLATED TRIM

The 24 carat gold plated finish on the trim requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abra- sive materials or chemical cleaners, as they may harm the finish and void the warranty.

Clean any fingerprints off before turning the unit on. If the top louvers start to discolour, check the door gasket seal and replace if necessary.

DOOR GLASS

Your FPI insert is supplied with high tempera- ture, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, and follow our step- by-step instructions for replacement.

Warning: Do not operate appliance with glass panels removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Caution: Wear gloves when removing damaged or broken glass.

Flush Glass Replacement

Remove the flush door front (as per instruc- tions on page 11). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame.

U32-2 FPI Direct Vent Gas Insert

19

Image 19
Contents U32 Gas Insert To the NEW Owner FPI GAS InsertTable of Contents Safety Label Installation Materials Required Minimum Fireplace Dimensions Clearances to CombustiblesManufactured Mobile Home Additional Requirements GAS Connection Flue Liner InstallationVenting Natural Gas Propane GAS Pipe Pressure TestingGAS Insert Aeration System Optional Brick PanelLOG SET Installation Rear View Trim Assembly Diagram Faceplate & Trim InstallationRear View Faceplate Assembly Diagram Standard Flush Door Optional Double Door Fire ScreenRobert Shaw Extension knobs for Bay Front only Optional BAY DoorOptional BAY Trim Removing Bay DoorHampton Cast Faceplate Installation U32 Grill Stop Bracket Hampton Cast Faceplate Grill InstallationSide Hook Diagram Slots Hampton Logo Left Hand Side Faceplate DiagramFinal Check Thermostat Wire TableOptional Remote Control Electrical Grounding Instructions Wiring DiagramOperating Instructions Copy of Lighting Instruction Plate Maintenance InstructionsMaintenance Grate screws FAN MaintenanceBay Glass Removal To remove fanHeat Gasket Shield Valve ReplacementInstall a new gasket and reinstall the valve assembly Shut off the gas supplyMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay DoorFaceplate Assembly Hampton Cast Faceplate Assembly Warranty Lifetime WarrantyInstaller Please complete the following information