Hampton Direct U32-LP2 Materials Required, Manufactured Mobile Home Additional Requirements

Page 6

INSTALLATION

1)Check all clearances to combustibles, page 6.

2)Make the gas connection. See page 7.

3)Install the 3" flue liner to the sliding connec- tor plate. See page 7.

4)Slide the unit half way into the fireplace.

5)Pull the vent connector plate through the tapered brackets and fasten to the front plate. See page 7.

6)Slide the unit fully into the fireplace.

7)Test gas pressure, page 8. Check aeration system, page 8.

8)Install the optional brick panels. See page 8.

9)Install the log set. See page 9.

10)Assemble and install the faceplate and trim. See page 10.

MATERIALS REQUIRED

No electrical power supply is required for the gas control to operate. A 120 Volt AC power cord is hooked up to the fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circum- stances. When connected with 120 volts, the appliance must be electrically grounded in ac- cordance with local codes, current version of CSA C22.1 (in Canada) or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70-1987.

NOTE: This unit is equipped with a heat sensor thermodisc which will prevent the blower from operat- ing until the unit reaches the cor- rect temperature.

MINIMUM FIREPLACE

DIMENSIONS

CLEARANCES TO COMBUSTIBLES

Minimum Clearances to Combustibles

From Unit

 

Sides

A

10" / 255 mm

Ceiling

B

47.5" / 1205 mm

Mantel

C

see Dia. 2 & 3

From Standard Surround (26" x 40")

Sides

D

4" / 100 mm

Ceiling

E

41.5" / 1055 mm

Mantel

 

see Dia. 2 & 3

Max. Mantle Depth

G

12" / 305 mm

 

 

(see Dia. 2)

Hearth Height

H

0" / 0 mm

Hearth Depth

I

16" / 405 mm

Hearth Width

J

40" / 1015 mm

Min. Alcove Width

K

48" / 1220 mm

Max. Alcove Depth

L

36" / 915 mm

11)Install the glass front (flush or bay). See pages 10 and 11.

12)Install optional glass trim, or door fire screens. See pages 11 and 12.

13)Install both louvers (flush or bay). See pages 11 and 12.

14)Install optional remote control or wall ther- mostat, pages 15.

15)Final check: Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This in- cludes:

a)Clocking the appliance to ensure the correct firing rate.

b)Adjusting the primary air, if required, to ensure that the flame does not carbon. See page 8.

c)Ensuring that the appliance is venting correctly.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided.

3)Appliance must be anchored to the floor with the supplied anchoring methods.

The minimum fireplace clearances & dimen- sions for the FPI gas insert are shown in the following diagrams:

Diagram 1

Combustible Mantel Clearances

with Bay & Flush Louvers in

Masonry and Factory Built

Fireplace Installation

*Note: If you are installing the Molded Faceplate, the minimum fireplace dimen- sions are as follows:

Width (at front): 29"

(737mm)

Depth:

15"

(381mm)

Diagram 2

6

U32-2 FPI Direct Vent Gas Insert

Image 6
Contents U32 Gas Insert FPI GAS Insert To the NEW Owner Table of Contents Safety Label Installation Minimum Fireplace Dimensions Clearances to Combustibles Materials RequiredManufactured Mobile Home Additional Requirements Flue Liner Installation GAS ConnectionVenting Optional Brick Panel GAS Pipe Pressure TestingGAS Insert Aeration System Natural Gas PropaneLOG SET Installation Faceplate & Trim Installation Rear View Trim Assembly DiagramRear View Faceplate Assembly Diagram Optional Double Door Fire Screen Standard Flush DoorRemoving Bay Door Optional BAY DoorOptional BAY Trim Robert Shaw Extension knobs for Bay Front onlyHampton Cast Faceplate Installation Hampton Logo Left Hand Side Faceplate Diagram Hampton Cast Faceplate Grill InstallationSide Hook Diagram Slots U32 Grill Stop BracketControl Thermostat Wire TableOptional Remote Final CheckWiring Diagram Electrical Grounding InstructionsOperating Instructions Maintenance Instructions Copy of Lighting Instruction PlateMaintenance To remove fan FAN MaintenanceBay Glass Removal Grate screwsShut off the gas supply Valve ReplacementInstall a new gasket and reinstall the valve assembly Heat Gasket ShieldParts List Main AssemblyBurner Assembly & LOG SET Bay Door Flush DoorFaceplate Assembly Hampton Cast Faceplate Assembly Warranty Warranty LifetimeInstaller Please complete the following information