Hampton Direct U32-NG2, U32-LP2 installation manual Installation

Page 5

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The FPI Gas Insert must be installed in accord- ance with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to deter- mine the need for a permit prior to starting the installation.

NOTE: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these in- structions may also void your fire insurance and/or warranty.

FOR YOUR SAFETY

This appliance requires air for proper combus- tion. Always provide adequate combustion and ventilation air. Follow instructions and information in CAN/CGA B149 (in Canada) or the National Fuel Gas Code ANSI Z223.1 (in the USA), regarding requirements for combustion and ventilation air.

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit must be disconnected.

Gas Input Capacity:

 

Natural Gas

30,000

Btu/h

Propane

30,000

Btu/h

Min. Input

 

 

Natural Gas

15,300

Btu/h

Propane

15,000

Btu/h

Fuels: Approved for use with both natural gas, and propane. Approved as is for use at 0' to 4,500' (0-1370m).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 110 CFM.

Log Set: Ceramic fibre, 7 per set.

Vent System: 3" co-linear aluminum flex.

The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independent of any installed sys- tem.

GAS PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than

1/2 psig. (3.45 kPa).

INSTALLATION INTO A SOLID FUEL BURNING FIREPLACE OR FACTORY BUILT FIREPLACE

The U32-2 Gas Inserts have been tested and approved to be vented into any masonry fire- place or approved solid fuel burning factory built fireplace that will allow the insert to phys- ically fit into the firebox. Refer to page 6 for minimum fireplace clearances.

If the factory built fireplace* height is too low for your Insert, you may remove the smoke baffle plate, damper, refractory (firebricks), glass doors, screen rails, screen mesh and log grates from the factory built fireplace as long as these items are saved and are reinstalled in the event that the Insert is removed.

Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. If any part is removed it must not weaken the structural integrity of the factory built fireplace.

NOTE: Any alterations made to the listed solid fuel burning factory built fireplace may void the listing of the fireplace.

*Check with your local inspector before com- mencing with this installation.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

General Safety Information

1)The appliance installation must conform with local codes or in the absence of local codes, with CAN/CGA B149 (in Canada) or the National Fuel Gas Code ANSI Z223.1 in the U.S.A. This appliance should be in- stalled by a qualified gas fitter technician only.

2)Installation and repair should be done by a qualified service person.

3)The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, animal hair, etc. It is imperative that control compart- ments, burners and circulating air pas- sageways of the appliance be kept clean.

4)See general construction and assembly instructions. This appliance may only be installed in a vented, noncombustible fire- place.

5)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6)Always connect this insert to a vent system venting to the outside of the building enve- lope. Never vent to another room or inside a building. Make sure that the vent is properly sized and is of adequate height to provide the proper draft.

7)Inspect the venting system annually for blockage and any signs of deterioration.

8)Any glass removed for servicing must be replaced prior to operating the appliance.

9)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

10)Due to high temperatures, the appliance should be located out of high traffic areas and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures, especially the fireplace glass and gold trims, and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or otherflammablematerialshouldnotbeplaced on or near the appliance.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

Before installing vent system ensure that the damper plate is open and secure to prevent the damper plate from falling down and crushing the liner.

The FPI Gas Insert is installed as listed below.

U32-2 FPI Direct Vent Gas Insert

5

Image 5
Contents U32 Gas Insert To the NEW Owner FPI GAS InsertTable of Contents Safety Label Installation Manufactured Mobile Home Additional Requirements Minimum Fireplace Dimensions Clearances to CombustiblesMaterials Required Venting Flue Liner InstallationGAS Connection GAS Insert Aeration System GAS Pipe Pressure TestingOptional Brick Panel Natural Gas PropaneLOG SET Installation Rear View Faceplate Assembly Diagram Faceplate & Trim InstallationRear View Trim Assembly Diagram Standard Flush Door Optional Double Door Fire ScreenOptional BAY Trim Optional BAY DoorRemoving Bay Door Robert Shaw Extension knobs for Bay Front onlyHampton Cast Faceplate Installation Side Hook Diagram Slots Hampton Cast Faceplate Grill InstallationHampton Logo Left Hand Side Faceplate Diagram U32 Grill Stop BracketOptional Remote Thermostat Wire TableControl Final CheckElectrical Grounding Instructions Wiring DiagramOperating Instructions Copy of Lighting Instruction Plate Maintenance InstructionsMaintenance Bay Glass Removal FAN MaintenanceTo remove fan Grate screwsInstall a new gasket and reinstall the valve assembly Valve ReplacementShut off the gas supply Heat Gasket ShieldMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay DoorFaceplate Assembly Hampton Cast Faceplate Assembly Warranty Lifetime WarrantyInstaller Please complete the following information