Hampton Direct U32-NG2, U32-LP2 Optional Remote, Control, Final Check, Thermostat Wire Table

Page 15

INSTALLATION

OPTIONAL WALL

OPTIONAL REMOTE

THERMOSTAT

CONTROL

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is firing

A wall thermostat may be installed if desired, follow the wiring diagram below. FPI offers an optional programmable thermostat but any 250- 750 millivolt rated non-anticipator type thermo- stat that is CSA, ULC or UL approved may be used.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50 Ft.

16 GA.

32 Ft.

18 GA.

20 Ft.

20 GA.

12 Ft.

22 GA.

9 Ft.

 

 

CAUTION

Do not connect the millivolt wall

thermostat wires to the 120V wires.

Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table.

2)Connect the wires as per the wiring dia- grams below.

CAUTION

Do not connect the millivolt

remote control wires for

to the 120V wires.

3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

correctly. This includes:

1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15 min. to stabilize.

3)Check for proper draft.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the manufacturer.

U32-2 FPI Direct Vent Gas Insert

15

Image 15
Contents U32 Gas Insert To the NEW Owner FPI GAS InsertTable of Contents Safety Label Installation Minimum Fireplace Dimensions Clearances to Combustibles Materials RequiredManufactured Mobile Home Additional Requirements Flue Liner Installation GAS ConnectionVenting Natural Gas Propane GAS Pipe Pressure TestingGAS Insert Aeration System Optional Brick PanelLOG SET Installation Faceplate & Trim Installation Rear View Trim Assembly DiagramRear View Faceplate Assembly Diagram Standard Flush Door Optional Double Door Fire ScreenRobert Shaw Extension knobs for Bay Front only Optional BAY DoorOptional BAY Trim Removing Bay DoorHampton Cast Faceplate Installation U32 Grill Stop Bracket Hampton Cast Faceplate Grill InstallationSide Hook Diagram Slots Hampton Logo Left Hand Side Faceplate DiagramFinal Check Thermostat Wire TableOptional Remote ControlElectrical Grounding Instructions Wiring DiagramOperating Instructions Copy of Lighting Instruction Plate Maintenance InstructionsMaintenance Grate screws FAN MaintenanceBay Glass Removal To remove fanHeat Gasket Shield Valve ReplacementInstall a new gasket and reinstall the valve assembly Shut off the gas supplyMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay DoorFaceplate Assembly Hampton Cast Faceplate Assembly Warranty Lifetime WarrantyInstaller Please complete the following information