Important Safety Instructions
Professional Outdoor Grills & Cooktops
WARNING: SAFETY PRECAUTIONS
Do not use the grill until a leak test has been performed.
WARNING:
TEST FOR LEAKS
A complete gas tightness check must be performed at the installation site.
To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area while performing a leak test . Perform leak test outdoors only. Never perform a leak test with fire or flame. DO NOT SMOKE WHILE PERFORMING THE LEAK TEST.
•Create a soapy solution of equal parts mild dishwashing detergent and water.
•Check to be sure all controls are in the OFF position.
•Turn on the fuel supply. For natural gas, turn manual
•Apply soap solution generously on all connections and fittings. See illustrations.
•If growing bubbles appear on any connection point, IMMEDIATELY turn off the gas supply.
To stop a gas leak:
•Turn on control knobs to release pressure. Turn controls OFF.
•Wash off soapy solution and towel dry.
•Tighten the loose joint and perform a new leak test .
Natural Gas Leak
Test Points
LP Gas Leak
Test Points
8