Napoleon Grills PRO 500 manual Safe Operating Practices

Page 3

3

WARNING! Failure to follow these instructions could result in property damage, personal injury or death. Read and follow all warnings and instructions in this manual prior to operating grill.

Safe Operating Practices

This gas grill must be assembled exactly according to the instructions in the manual. If the grill was store assembled, you must review the assembly instructions to confirm correct assembly and perform the required leak tests before operating the grill.

Read the entire instruction manual before operating the gas grill.

This gas grill must be used only outdoors in a well-ventilated space and must not be used inside a building, garage, screened-in porch, gazebo or any other enclosed area.

This gas grill must not be installed in or on recreational vehicles and/or boats.

Do not locate unit in windy settings. High winds adversely affect the cooking performance of the gas grill.

Under no circumstances should this gas grill be modified.

Do not operate unit under overhead combustible construction.

Maintain proper clearance to combustibles (20” (508mm) to rear of unit, 7” (178mm) to sides). Additional clearance of (24” (610mm) is recommended near vinyl siding or panes of glass.

Gas must be turned off at the propane cylinder or at the natural gas supply valve when the gas grill is not in use.

Do not attempt to use a cylinder that is not equipped with a QCC1 type connection.

When the propane cylinder is connected to the appliance, the gas grill and cylinder must be stored outdoors in a well-ventilated space.

When the gas grill is to be stored indoors, the connection between the propane cylinder and the gas grill must be disconnected and the cylinder removed and stored outdoors in a well ventilated space out of reach of children. Disconnected cylinders must not be stored in a building, garage or any other enclosed area. Natural gas units must be disconnected from the supply when being stored indoors.

Inspect the fuel supply hose before each use. If there is evidence of excessive abrasion or wear or the hose is cut, it must be replaced prior to using the gas grill with a replacement pressure regulator and hose assembly specified by the grill manufacturer.

Do not route hose underneath drip pan - proper hose clearance to bottom of unit must be maintained.

Hose must not run behind the front leg. It must run around the front side of leg (if applicable).

Leak test the unit before initial use, annually, and whenever any gas components are replaced.

Follow lighting instructions carefully when operating grill.

Burner controls must be off when turning supply cylinder valve on.

The lid is to be closed during the gas grill preheating period on all models except the BISZ300NFT/PFT and the built-in side burner BISB245.

The BISZ300NFT/PFT and the built-in side burner BISB245 are supplied with a flat cover for storage and protection from the elements. Never place this cover on the grill while hot or operating. Allow grill to cool completely before covering.

Adults and especially children should be alerted to the hazards of high surface temperatures. Young children should be supervised near the gas grill.

Do not leave grill unattended when operating.

Do not light burners with lid closed.

Do not operate rear burner with main burners operating.

Do not move grill when hot or operating.

Do not use condiment tray to store lighters, matches or any other combustibles.

Keep any electrical supply cord and fuel supply hose away from any heated surfaces.

Ensure sear plates are positioned properly according to sear plate installation instructions. The holes must be towards the front of the gas grill (if applicable).

Clean grease tray and sear plates regularly to avoid build-up, which could lead to grease fires.

Remove warming rack before lighting rear burner. The extreme heat will damage the warming rack.

Inspect infrared burner venturi tube for spider webs and other obstructions periodically. Clean the tubes completely if you find any such obstructions.

Do not allow cold water (rain, sprinkler, hose, etc.) to come in contact with heated unit. A large temperature differential can cause chipping in the porcelain.

Do not allow cold water (rain, sprinkler, hose, etc.) to come in contact with ceramic burners.

Do not use a pressure washer to clean any part of the unit.

www.napoleongrills.com

Image 3
Contents If YOU Smell GAS PRONapoleon GAS Grill PRESIDENT’S Limited Lifetime Warranty Safe Operating Practices Dimensions Propane Cylinder Specifications General InformationGas Hook-Up Instructions Page Leak Testing Instructions Lighting Instructions Cooking Instructions Replacement Screen N565-0002 Infrared Heat Infrared Grilling ChartCleaning Instructions Maintenance Instructions Page Replacement Screen N565-0002 Problem Possible Causes Solution TroubleshootingPressure to equalize. See lighting instructions Ordering Replacement Parts Warranty InformationRecord information here for easy reference Avertissement Conditions Et Limitations Garantie À VIE Limitée DU PrésidentPratiques Sécuritaires D’utilisation Dimensions Information Générale Instructions De Branchement Du GazSpécifications Pour La Bonbonne De Propane Avertissement Test De Détection De Fuites Fermez Instruction D’allumageInstructions D’opération Écrans de rechange N565-0002 Tableau de cuisson à l’infrarouge Chaleur InfrarougeNettoyage Pour ajuster le volet d’air Instructions D’entretienÉcrans de rechange N565-0002 Guide De Dépannage Problème Causes possibles SolutionsLa peinture semble Accumulation de graisse sur les Commande De Pièces De Rechange Information Sur La GarantieInscrivez l’information ici pour y avoir accès facilement Pour Commencer Getting StartedN570-0086 #14 x 1/2 810mm Propane Only Propane Seulement Propane Only N570-0086 #14 x 1/2 Disposable grease tray jetable du récipient à graisse N570-0086 #14 x 1/2 810mm N430-0002 N570-0038 1/4-20 X 1/2 810mm N105-0015 Page AVERTISSEMENT! Ne serrez pas 500RSIB N715-0093 N520-0035 N305-0085 Instructions D’assemblage De L’ensemble De Rôtissoire Rotisserie Kit Assembly InstructionN160-0002 Page Leak Testing Instructions Test De Détection De Fuites Parts List / Liste DES Pièces PRO500RB Description 500RB Parts List / Liste DES Pièces PRO500RB Parts Diagram / Liste DES Pièces PRO500RB Parts List / Liste DES Pièces PRO500RSIB Parts List / Liste DES Pièces PRO500RSIB Standard Propane units only Compris Parts Diagram / Liste DES Pièces PRO500RSIB Accessories & Parts Order Form BON DE Commande Pour PIÈCES/ACCESSOIRES N415-0248