Napoleon Grills PRO 500 manual Leak Testing Instructions

Page 52

52

Leak Testing Instructions

WARNING! A leak test must be performed annually and each time a cylinder is hooked up or if a part of the gas system is replaced.

WARNING! Never use an open flame to check for gas leaks. Be certain no sparks or open flames are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to property, serious bodily injury, or death.

Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.

Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.

Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended by the Napoleon Customer Care department and have the grill inspected by a certified gas installer.

If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.

www.napoleongrills.com

Image 52
Contents PRO If YOU Smell GASNapoleon GAS Grill PRESIDENT’S Limited Lifetime Warranty Safe Operating Practices Dimensions General Information Propane Cylinder SpecificationsGas Hook-Up Instructions Page Leak Testing Instructions Lighting Instructions Cooking Instructions Replacement Screen N565-0002 Infrared Grilling Chart Infrared HeatCleaning Instructions Maintenance Instructions Page Replacement Screen N565-0002 Troubleshooting Problem Possible Causes SolutionPressure to equalize. See lighting instructions Warranty Information Ordering Replacement PartsRecord information here for easy reference Avertissement Garantie À VIE Limitée DU Président Conditions Et LimitationsPratiques Sécuritaires D’utilisation Dimensions Instructions De Branchement Du Gaz Information GénéraleSpécifications Pour La Bonbonne De Propane Avertissement Test De Détection De Fuites Instruction D’allumage FermezInstructions D’opération Écrans de rechange N565-0002 Chaleur Infrarouge Tableau de cuisson à l’infrarougeNettoyage Instructions D’entretien Pour ajuster le volet d’airÉcrans de rechange N565-0002 Problème Causes possibles Solutions Guide De DépannageLa peinture semble Accumulation de graisse sur les Information Sur La Garantie Commande De Pièces De RechangeInscrivez l’information ici pour y avoir accès facilement Getting Started Pour CommencerN570-0086 #14 x 1/2 810mm Propane Only Propane Seulement Propane Only N570-0086 #14 x 1/2 Disposable grease tray jetable du récipient à graisse N570-0086 #14 x 1/2 810mm N430-0002 N570-0038 1/4-20 X 1/2 810mm N105-0015 Page AVERTISSEMENT! Ne serrez pas 500RSIB N715-0093 N520-0035 N305-0085 Rotisserie Kit Assembly Instruction Instructions D’assemblage De L’ensemble De RôtissoireN160-0002 Page Leak Testing Instructions Test De Détection De Fuites Parts List / Liste DES Pièces PRO500RB Description 500RB Parts List / Liste DES Pièces PRO500RB Parts Diagram / Liste DES Pièces PRO500RB Parts List / Liste DES Pièces PRO500RSIB Parts List / Liste DES Pièces PRO500RSIB Standard Propane units only Compris Parts Diagram / Liste DES Pièces PRO500RSIB Accessories & Parts Order Form BON DE Commande Pour PIÈCES/ACCESSOIRES N415-0248