Desa CDCFNRA, CDCFPRA Continued, ON/OFF SERIES MODEL HRC101, THERMOSTAT SERIES MODEL HRC201

Page 24
Figure 40 - Setting the Selector Switch,

OPERATING FIREPLACE

Continued

Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

FlameControl

Adjustment Knob Knob

OUT IN

REMOTE

 

OFF

 

ON

LO

Selector Switch in Remote Position (Optional Remote Control)

Figure 40 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

ON/OFF SERIES (MODEL HRC101)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 41).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

THERMOSTAT SERIES (MODEL HRC201)

The hand-held remote can be operated using either the manual mode (MANU) or thermo- static mode (AUTO) (see Figure 42). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by press- ing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center

of the room facing towards the fireplace.

 

Digital Display Shows

 

Temperature and Settings

Locks

 

AUTO

ROOM

 

SET

System to

TEMP

 

TEMP

Prevent

LOCK

 

POWER

Accidental

TEMP

Ignition

 

 

 

Indicator

Control

Button

Light

 

Figure 41 - ON/OFF Hand-Held Remote Control Unit

Turns Control Knob and Flame Adjustment Burners On or Off

Increases or Decreases Room Temperature in AUTO Mode

MANU

ºC/ºF

AUTO

 

 

 

 

Turns

 

 

Hand-Held

 

 

Remote On

 

 

or Off and

°C/°F

 

Allows You

Selects

to Choose

Mode

the Manual

AUTO

Button

Setting

Mode

 

 

Figure 42 - Thermostat Hand-Held Remote Control Unit

24

www.desatech.com

116658-01A

Image 24
Contents WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance TABLE OF CONTENTS 116658-01ASAFETY INFORMATION DANGER Carbon monoxide poisoning may lead to deathWARNING Any change to this fireplace or its controls can be dangerous CONTROL ACCESSORIES See Accessories, pageOPTIONAL REMOTE Continueddiagrams or failure to use only SAFETY PILOTWARNING Always have fireplace. This prevents excesb. weather stripping has been added on openable windows and doors and PROVIDING ADEQUATE VENTILATIONFigure 3 - Assembling Hood Unusually Tight ConstructionDETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space WARNING Never install the fireplace in a bedroom or bathroom in a recreational vehicleas a fireplace insert in high traffic areas in windy or drafty areas VENTILATION AIRINSTALLATION ITEMS Before installing fireplace, make sure you have the items listed belowexternal regulator supplied by installer, for propane/LP units only CHECK GAS TYPECAUTION If you install the fireplace in a home garage locate fireplace where moving vehicle will not hit itBUILT-IN FIREPLACE INSTALLATION Figure 7 - Rough Opening for Installing in WallNote A qualified installer should make all electri- cal connections 4. If you have not installed hood, follow instruc- tions on page7. Bend four nailing flanges on outer casing with pliers see Figure Figure 9 - Attaching Fireplace to Wall StudsOPTIONAL MANTEL INSTALLATION of the following raise the mantel to an accept- able heightremove the mantel INSTALLING OPTIONAL BLOWER ACCESSORY GA3450TA Figure 12 - Attaching Brass Trim to FireplaceFigure 13 - Assembling Brass Trim Installing Blower Accessory Screw Figure 16 - Installing Switch Plate to Remote/Blower BracketCAUTION Verify proper op- eration after servicing For Built-In Installation Figure 17 - Installing Blower Bracket AssemblyFigure 18 - Wiring Diagram For Blower Accessory Built-In Installation CONNECTING TO GAS SUPPLY installing or servicing. Correct WARNING Test all gas pipingand connections, internal and external to unit, for leaks afterPRESSURE TESTING GAS SUPPLY PIPING SYSTEM PRESSURE TESTING FIREPLACE GAS CONNECTIONSFigure 24 - Checking Gas Joints Propane/LP Only Figure 25 - Checking Gas Joints Natural Gas OnlyOPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES Figure 26 - Disconnecting Wires From Control ValveFigure 28 - Installing Remote Receiver OPTIONAL WALL MOUNTED THERMOSTAT - GWMT17. Install the base onto the wall with the provided screws Figure 30 - Connecting Wire Terminals“W” and “R” OPTIONAL WALL SWITCH - GWMS2 1. Remove jumper wire from control valve see Figure 26, pageFigure 33 - Installing Rear Brick Liner Figure 35 - Installing LogFigure 36 - Installing Screen Figure 34 - Installing Side Brick LinersFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACELIGHTING INSTRUCTIONS MANUAL LIGHTING PROCEDURE 2. If Using Optional Hand-Held RemoteTO TURN OFF GAS TO APPLIANCE OPTIONAL HAND-HELD REMOTE OPERATIONFigure 40 - Setting the Selector Switch Control Knob and Flame Adjustment Knob for Remote Operation3. Press the POWER and LOCK buttons together to turn off the fireplace 4. Press the POWER and LOCK buttons together to turn off the fireplaceOPTIONAL GWMS2 WALL MOUNTED SWITCH see Troubleshooting, pageOPTIONAL GWMT1 WALL MOUNTED THERMOSTAT PILOT FLAME PATTERNWARNING Turn off fireplace and let cool before cleaning CONTINUEDBURNER FLAME PATTERN BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLELOG SET CABINETFigure 48 - Pilot Inlet Air Hole Propane/LP Gas Figure 49 - Pilot Inlet Air Hole Natural GasTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYOBSERVED PROBLEM POSSIBLE CAUSE see Cleaning and Mainte WARNING If you smell gas Shut off gas supply Do not try to light any applianceIf you cannot reach your gas supplier, call the fire department SPECIFICATIONS Remote-Ready ModelsCDCFPRA CDCFNRAREPLACEMENT PARTS SERVICE HINTSTECHNICAL SERVICE PARTS UNDER WARRANTYPARTS BREAKDOWNILLUSTRATED MODELS FIREBOX CDCFNRAPARTS LIST FIREBOX MODELS CDCFNRA, CDCFPRAILLUSTRATED PARTS BREAKDOWN NaturalGas Only REMOTE-READY MODELS NOTICE All accessories may not be available for all fireplace models THERMOSTAT-CONTROLLED BLOWER KIT GA3450TAEQUIPMENT SHUTOFF VALVE GA5010 BRASS TRIM KIT - GA6095CLEANING KIT - GCK/CCK WALL-MOUNT THERMOSTAT SWITCH GWMT1WALL-MOUNT ON/OFF SWITCH GWMS2 RECEIVER AND HAND-HELD REMOTE CONTROL KIT - HRC100 AND HRC10112701 Industrial Drive P.O. Box NOT A UPC 116658-01 Rev. A 04/05116658