Desa EFS10TPA, EFS10TNA, VMH10TNC, VMH10TPC installation manual Optional Mantel Installation

Page 13

INSTALLATION

Continued

Mantel Shelf

Note:

10"

8"

All vertical

measurements

6"

are from top of

2 1/2"

fireplace

opening to bottom of mantel shelf. All measurements are in inches.

13"

16"

19"

21"

Side of Firebox

Figure 10 - Minimum Mantel Clearances

for Built-In Installation

OPTIONAL MANTEL INSTALLATION

Note: Refer to instructions provided with the man- tel for assembly instructions. Refer to the follow- ing instructions for system installation. Refer to instructions on page 5 for fireplace assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3450T, page 14).

1.Unscrew four screws that attach top louver to fireplace. Remove louver from fireplace and set aside.

2.Place fireplace on wood base.

3.Place mantel around fireplace/base assembly.

4.Assemble trim kit. See Assembling Trim, page 14.

5.Firmly snap trim kit on shoulder screws. Shoulder screws are located on fireplace cabi- net (see Figure 11).

6.Align trim kit for flush fit around opening.

7.Use two 3" wood screws provided and attach fireplace base to wooden base. There are holes provided on each side and floor of firebox (see Figure 11).

8.Place base assembly next to wall at installa- tion location.

9.Remove trim kit and mantel. Be careful not to damage wall or mantel.

10.Attach wood base to floor with two 1 3/4" black screws provided (see Figure 12). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 17).

11.Install gas line. See Connecting To Gas Sup- ply, page 17.

12.Check for leaks. See Checking Gas Connec- tions, page 19.

13.Place mantel around fireplace. Be careful not to damage wall or mantel.

14.Place trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the trim over the shoulder screws on fire- place (see Figure 11).

15.Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for the louvers (see Figure 11).

16.Reinstall top louvers.

Shoulder Screws

Hole for

Attaching

 

 

Fireplace

 

to Mantel

Assembled

Shoulder

Trim

Screws

Figure 11 - Attaching Trim to Fireplace

1 3/4" Screw

Wood Base

Figure 12 - Attaching Wood Base to

Floor

112462-01B

www.desatech.com

13

Image 13
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Optional Remote Control Accessories Product FeaturesProduct Identification UnpackingAssembling Fireplace AssemblyShoulder Screw Screen Hood Tabs Louver Baffle Sheet Metal Screws Firebox TopProviding Adequate Ventilation AIR for Combustion VentilationConfined and Unconfined Space Ventilation AIR Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingVentilation Air from Inside Building InstallationCheck GAS Type Installation ItemsFireplace Clearances Minimum Clearance to Combustible Materials BUILT-IN Fireplace InstallationExample If you have not assembled firebox, follow in- structions on Mantel Clearances for Built-In InstallationFlanges Optional Mantel Installation Installing Blower Accessory Installing Optional Blower Accessory GA3450TAssembling Trim Trim shipped with mantel Removing Upper LouverScrew Wiring Routing Hole Baffle Wire HarnessPower Cord Snap Bushing Extension Cord For Built-In InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyIncluded DoorPropane/LP Installation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaEquipment Shutoff Valve Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaClosed Equipment Gas Regulator orInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesInstalling 9-Volt Battery in Hand-Held Remote Control Unit Feed wires through rectangular slots Control Valve Jumper Wire One terminal of 25 ft. wireTerminal W Terminal R R Operating Fireplace Installing LOG SET and ScreenShoulder Screw Log Screen Electronic Ignitor Button Control Knob Lighting InstructionsThermocouple Ignitor Electrode Pilot Burner Ignitor ThermocoupleREMOTE-READY Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationPilot Ignitor Burner Electrode Control Knob Electronic IgnitorPilot Burner Ignitor Electrode ON/OFF Series Model Ghrcb Optional HAND-HELD Remote OperationThermostat Series Model Ghrctb GWMS2 Wall Mounted Switch OptionalGWMT1 Wall Mounted Thermostat Optional Pilot Flame Pattern Inspecting BurnersBurner Flame Pattern Pilot Burner ThermocoupleBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLOG SET CabinetTroubleshootiing Observed Problem Possible Cause RemedyTroubleshooting Residues from manufactur Bris. If found, clean burnerTial operation Hours of operationGas leak. See Warning Wiring Diagram SpecificationsReplacement Parts Service HintsIllustrated Parts Breakdown Install Battery According To This IllustrationTHERMOSTAT-CONTROLLED Models Parts List935 REMOTE-READY Models Accessories Receiver and HAND-HELD Thermostat Remote Control KIT Ghrctb WALL-MOUNT ON/OFF Switch GWMS2Receiver and HAND-HELD Remote Control KIT Ghrcb Corner Mantel with Full Hearth Base112462-01B 112462-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Classic Hearth Fireplace