OPERATING FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise Clockwise to the

OFF position.

2.If Using Optional Hand-Held Remote: Set remote switch to the OFF position to pre- vent draining battery.

Shutting Off Burner Only (pilot stays lit) You may shut off the burner and keep the pilot lit by doing one of the following:

1. Turn control knob clockwise Clockwise to the

PILOT position.

2.If Using Optional Hand-Held Remote: Use remote control manual OFF button.

WARNING: Make sure re- mote sensor selector switch is in the OFF position when you are away from home for long periods of time.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 26.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, page 26.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 40). Follow instructions included with the re- mote control.

NOTICE: You must light the pi- lot before using the hand-held remote control unit. See Light- ing Instructions on page 26.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Slide the remote selector switch to the REMOTE position (see Figure 43). Note: The burner may light if hand-held remote was on when the remote selector switch was last turned off. You can now turn the burner on and off with the hand-held re- mote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Selector Switch in

REMOTE

Position (Optional

Hand-Held

Remote Control)

Electronic

Control Knob

Ignitor

OFF

N

 

 

ON

 

 

O

 

O

REMOTE

O

 

 

T

FF

 

 

LIP

 

 

 

 

Figure 43 - Setting the Selector Switch and Control Knob for Hand-Held Remote Operation

ON/OFF SERIES (MODEL GHRCB)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 44).

TO LOCK press both buttons on hand-held re- mote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 44 - On/Off Hand-Held Remote

Control Unit (GHRCB)

112462-01B

www.desatech.com

27

Image 27
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Unpacking Product FeaturesOptional Remote Control Accessories Product IdentificationHood Tabs Louver Baffle Sheet Metal Screws Firebox Top AssemblyAssembling Fireplace Shoulder Screw ScreenAIR for Combustion Ventilation Providing Adequate VentilationConfined and Unconfined Space Ventilation Air From Inside Building Determining FRESH-AIR Flow for Fireplace LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air from Inside Building InstallationInstallation Items Check GAS TypeFireplace Clearances BUILT-IN Fireplace Installation Minimum Clearance to Combustible MaterialsExample Mantel Clearances for Built-In Installation If you have not assembled firebox, follow in- structions onFlanges Optional Mantel Installation Removing Upper Louver Installing Optional Blower Accessory GA3450TInstalling Blower Accessory Assembling Trim Trim shipped with mantelWire Harness Screw Wiring Routing Hole BafflePower Cord Snap Bushing Extension Cord For Built-In InstallationDoor Connecting to GAS SupplyAttaching Wood Base to Solid Floor IncludedPropane/LP Test Pressures In Excess Of 1/2 Psig 3.5 kPa Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsEquipment Gas Regulator or Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaEquipment Shutoff Valve ClosedOptional Wireless HAND-HELD Remote Control Accessories Installing ReceiverInstalling 9-Volt Battery in Hand-Held Remote Control Unit Control Valve Jumper Wire One terminal of 25 ft. wire Feed wires through rectangular slotsTerminal W Terminal R R Installing LOG SET and Screen Operating FireplaceShoulder Screw Log Screen Ignitor Thermocouple Lighting InstructionsElectronic Ignitor Button Control Knob Thermocouple Ignitor Electrode Pilot BurnerThermostat Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting To Turn OFF GAS To ApplianceControl Knob Electronic Ignitor Pilot Ignitor Burner ElectrodePilot Burner Ignitor Electrode ON/OFF Series Model Ghrcb Optional HAND-HELD Remote OperationGWMS2 Wall Mounted Switch Optional Thermostat Series Model GhrctbGWMT1 Wall Mounted Thermostat Optional Pilot Burner Thermocouple Inspecting BurnersPilot Flame Pattern Burner Flame PatternCabinet Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole LOG SETTroubleshootiing Observed Problem Possible Cause RemedyTroubleshooting Hours of operation Bris. If found, clean burnerResidues from manufactur Tial operationGas leak. See Warning Service Hints SpecificationsWiring Diagram Replacement PartsIllustrated Parts Breakdown Install Battery According To This IllustrationTHERMOSTAT-CONTROLLED Models Parts List935 REMOTE-READY Models Accessories Corner Mantel with Full Hearth Base WALL-MOUNT ON/OFF Switch GWMS2Receiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT Ghrcb112462-01B 112462-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Compact Classic Hearth Fireplace