16.Position wall switch assembly vertically over wall openings with decal lettering upright (see Figure 13).

17.Insert mounting screws, removed in step 2 of Relocating Wall Switch Assembly on pages 9 and 10, through holes in wall plate and into wall anchors.

18.Tighten screws until wall plate is firmly attached to wall. Do not overtighten.

Opening in

Wall or

Mantel Wall

Wall Switch Assembly

Screws

Figure 13 - Securing Wall Switch Assembly

Mounting Wall Switch Assembly to Side of Mantel

7.Create three openings in the mantel wall according to Tem- plate 2, page 33. This is best done by making a pattern to work with on the mantel. Carefully cut page 33/34 from manual and tape paper template vertically onto mantel wall at preferred location. Pierce the paper at the centers of the 2 holes with a nail or sharp pencil, leaving a mark on the wall. Do the same at centers of the four circles near the corners of the rectangle.

8.Remove paper template from mantel wall.

9.Drill 1/8" pilot holes at each mark for top and bottom screw holes. Drill 3/8" holes at each mark for centers of four circles near corners of rectangle.

10.Using a straight edge and pencil, connect the outer edges of the 4 holes for the rectangle (see Figure 10, page 10). This will give you cutting lines for the rectangle you will cut in the mantel wall.

11.Using a keyhole saw, hack saw blade, drill, file, or other suit- able tool, carefully cut out the rectangular opening. Note: The corners of the rectangle may be round. IMPORTANT: Do not exceed the size of the rectangle on template.

12.Carefully pass wall switch assembly through rectangular open- ing from inside mantel (see Figure 13).

13.Position wall switch assembly vertically over opening with decal lettering upright. Make sure wires freely pass through wall without binding. Align holes in wall plate with 1/8" pilot holes in mantel wall.

14.Drive mounting screws, removed in step 2 of Relocating Wall Switch Assembly on pages 9 and 10, through wall plate holes and into pilot holes in mantel wall.

15.Tighten screws until wall switch assembly is firmly attached to mantel. Do not overtighten.

INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

WARNING: For propane/LP units, never connect fireplace directly to propane/LP supply. This fire- place requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

WARNING: For natural gas units, never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer, for propane/LP units only)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, pages 30 and 31.

For propane/LP units, the installer must supply an external regula- tor. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent point- ing down as shown in Figure 14, page 12. Pointing the vent down protects it from freezing rain or sleet.

For morevisit www..com

110112-01A

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsOther gases Product IdentificationUnpacking Product FeaturesLocal Codes Confined Space and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionVentilation Air From Inside Building Determining FRESH-AIR Flow for Heater LocationVentilation AIR Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors InstallationCheck GAS Type Electrical Hookup Installation ClearancesInstallation Sequence Removing Fireplace Screen and Floor AssemblyElectrical Connections for Power Cord Relocating Wall Switch AssemblyRelocating Wall Switch Assembly Mounting Wall Switch Assembly to Side of Mantel Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsPressure Testing Gas Supply Piping System Hole Conventional Fireplace InstallationMantel Clearances for Built-In Installation BUILT-IN Fireplace InstallationAssembling and Attaching Optional Brass Trim Installing HoodInstalling Logs Installing Log #2 Right and Log #3 Left Installing Battery Into RemoteOperating Fireplace Installing ScreenFor Your Safety Read Before Lighting Using Supplied Wall Switch AssemblyManual Lighting Instructions For Electrical Power OutageTo Turn OFF GAS To Appliance Operating FAN Shutting Off Heater When Manually LitInspecting Burners Optional Blower OperationBurner Flame Patterns Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Logs SpecificationsObserved Problem Possible Cause Remedy TroubleshootingFor Com Gas leak. See Warning statement Illustrated Parts Breakdown Remote Control LOG Base Assembly Models VTGF33PRA VTGF33NRA Parts ListFireplace Models VTGF33NRA VTGF33PRA Fireplace Models VTGF33NRA and VTGF33PRA Accessories Firebox Brick Liner G8000 Series Cleaning KIT GCKSlim Hearth Base Laminate Trim for Hearth or MantelWiring Diagram Replacement PartsService Hints Technical ServiceDiameter Holes TemplatesThis page Intentionally Left Blank Owners Registration Form Postage Required 110112-01A Not a UPC