TROUBLESHOOTING

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

 

burner is lit

 

when burner is cold

 

let warm up for a minute

 

 

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

 

 

line. Have gas line checked by local

 

 

 

 

 

 

natural or propane/LP gas company

 

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

 

ances (see page 8)

 

 

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Main-

 

 

 

 

 

 

tenance, pages 21 and 22) or replace

 

 

 

 

 

 

burner orifice

 

 

 

 

 

 

 

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

 

spark at ODS/pilot (manual ignition mode)

 

tor cable

 

 

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

 

 

base panel

 

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

 

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

 

 

 

7.

Ignitor electrode positioned wrong

7.

Replace pilot assembly

 

 

 

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

 

spark at ODS/pilot but no ignition (manual

 

shutoff valve closed

 

shutoff valve

 

ignition mode)

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position full

 

 

 

 

 

 

counterclockwise

 

 

 

3.

Air in gas lines when installed

3.

Continue holding control knob in full

 

 

 

 

 

 

counterclockwise position. Repeat

 

 

 

 

 

 

igniting operation until air is removed

 

 

 

4.

Depleted gas supply (propane/LP only)

4.

Contact local propane/LP gas company

 

 

 

5.

ODS/pilot is clogged

5.

Clean ODS/pilot (see Cleaning and

 

 

 

 

 

 

Maintenance, pages 21 and 22) or re-

 

 

 

 

 

 

place ODS/pilot assembly

 

 

 

6.

Gas regulator setting is not correct

6.

Replace gas regulator

 

 

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully turned counter-

1.

Turn control knob fully counterclock-

 

control knob is released (manual ignition

 

clockwise

 

wise

 

mode)

2.

Control knob not held long enough

2.

After ODS/pilot lights, hold control

 

 

 

 

 

 

knob for 30 seconds

 

 

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

 

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local natural or propane/LP

 

 

 

 

which allows thermocouple to cool,

 

gas company

 

 

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

 

 

lem could be caused by one or both of

 

Maintenance, pages 21 and 22) or re-

 

 

 

 

the following:

 

place ODS/pilot assembly

 

 

 

 

A) Low gas pressure

 

 

 

 

 

 

 

B) Dirty or partially clogged OD S/pilot

 

 

 

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten

 

 

 

 

trol valve

 

1/4 turn more

 

 

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

 

 

7.

Control valve damaged

7.

Replace control valve

 

 

For

 

.

 

.com

110112-01A

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesProduct Features Local CodesUnpacking AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Ventilation AIRDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingInstallation Check GAS TypeVentilation Air From Outdoors Installation Clearances Installation SequenceRemoving Fireplace Screen and Floor Assembly Electrical HookupRelocating Wall Switch Assembly Electrical Connections for Power CordRelocating Wall Switch Assembly Installing GAS Piping to Fireplace Location Mounting Wall Switch Assembly to Side of MantelConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Conventional Fireplace Installation HoleBUILT-IN Fireplace Installation Mantel Clearances for Built-In InstallationInstalling Hood Installing LogsAssembling and Attaching Optional Brass Trim Installing Battery Into Remote Installing Log #2 Right and Log #3 LeftInstalling Screen For Your Safety Read Before LightingUsing Supplied Wall Switch Assembly Operating FireplaceFor Electrical Power Outage To Turn OFF GAS To ApplianceManual Lighting Instructions Shutting Off Heater When Manually Lit Inspecting BurnersOptional Blower Operation Operating FANCleaning Maintenance Cleaning Burner Injector Holders and Pilot AIR Inlet HolesBurner Flame Patterns Specifications LogsTroubleshooting Observed Problem Possible Cause RemedyFor Com Gas leak. See Warning statement Illustrated Parts Breakdown Parts List Remote Control LOG Base Assembly Models VTGF33PRA VTGF33NRAFireplace Models VTGF33NRA VTGF33PRA Fireplace Models VTGF33NRA and VTGF33PRA Accessories Cleaning KIT GCK Slim Hearth BaseLaminate Trim for Hearth or Mantel Firebox Brick Liner G8000 SeriesReplacement Parts Service HintsTechnical Service Wiring DiagramTemplates Diameter HolesThis page Intentionally Left Blank Owners Registration Form Postage Required 110112-01A Not a UPC