Desa VTGF33NRA Operating Fireplace, Installing Screen, For Your Safety Read Before Lighting

Page 18

18

INSTALLATION

Installing Screen

OPERATING FIREPLACE

For Your Safety Read Before Lighting Normal Lighting Instructions

INSTALLATION

Continued

INSTALLING SCREEN

Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 36).

Screws for

Mounting Screen

Notches

Figure 36 - Installing Fireplace Screen

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which lights automatically when using the supplied wall switch or remote control. If you have a power outage, the pilot may be lighted by hand with push-button piezo ignitor. When lighting the pilot, the fol- lowing warnings must be followed.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Electric Power Outage Only: Use only your hand to turn the manual override handle on the gas control knob. Never use tools. If the knob will not turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

NORMAL LIGHTING

INSTRUCTIONS

WARNING: You must operate this heater with the fireplace screen in place. Make sure fireplace screen is in place before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Fol- low “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.

A. Using Supplied Wall Switch Assembly

1.Set manual ignition bypass switch on the control panel to the OFF position (automatic ignition position).

2.Press ON/OFF button. Hold for 6 seconds. Gas valve will open and electronic ignition will begin sparking to light pilot. LED will light. Note: You may be running this heater for the first time after connecting to gas supply or at the start of your heating season. If so, the ON/OFF button may need to be pressed again. This will allow air to bleed from gas system. If several attempts to light pilot fail, contact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instructions for Electric Power Outage, pages 19 and 20).

3.When pilot flame is lit, the thermocouple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automatically light on high flame.

For..com

110112-01A

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesProduct Features Local CodesUnpacking Unusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined Space and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingInstallation Check GAS TypeVentilation Air From Outdoors Removing Fireplace Screen and Floor Assembly Installation ClearancesInstallation Sequence Electrical HookupRelocating Wall Switch Assembly Electrical Connections for Power CordRelocating Wall Switch Assembly Installing GAS Piping to Fireplace Location Mounting Wall Switch Assembly to Side of MantelConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Conventional Fireplace Installation HoleBUILT-IN Fireplace Installation Mantel Clearances for Built-In InstallationInstalling Hood Installing LogsAssembling and Attaching Optional Brass Trim Installing Battery Into Remote Installing Log #2 Right and Log #3 LeftUsing Supplied Wall Switch Assembly Installing ScreenFor Your Safety Read Before Lighting Operating FireplaceFor Electrical Power Outage To Turn OFF GAS To ApplianceManual Lighting Instructions Optional Blower Operation Shutting Off Heater When Manually LitInspecting Burners Operating FANCleaning Maintenance Cleaning Burner Injector Holders and Pilot AIR Inlet HolesBurner Flame Patterns Specifications LogsTroubleshooting Observed Problem Possible Cause RemedyFor Com Gas leak. See Warning statement Illustrated Parts Breakdown Parts List Remote Control LOG Base Assembly Models VTGF33PRA VTGF33NRAFireplace Models VTGF33NRA VTGF33PRA Fireplace Models VTGF33NRA and VTGF33PRA Accessories Laminate Trim for Hearth or Mantel Cleaning KIT GCKSlim Hearth Base Firebox Brick Liner G8000 SeriesTechnical Service Replacement PartsService Hints Wiring DiagramTemplates Diameter HolesThis page Intentionally Left Blank Owners Registration Form Postage Required 110112-01A Not a UPC