LOCAL CODES

4 UNPACKING PRODUCT FEATURES

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.

1.With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the carton off the heater. Re- move packing. Note: The hood is located in the packing on the right hand side of the heater front. Lift the heater off the bottom tray.

2.Locate two screws above top corners of the fireplace screen. Remove and discard these screws. Lift fireplace screen up and pull out to remove.

3.Remove protective packaging applied to logs, log base assem- bly, and fireplace.

4.Remove fireplace hood from carton insert.

5.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glowing embers. When used without the optional blower, the fireplace requires no electricity making it ideal for emergency backup heat.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot system shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.

WIRELESS REMOTE CONTROL

This fireplace features an infrared wireless remote control. This control system can be used to automatically light the pilot and adjust the burner flame height at the push of a button.

WIRED WALL-MOUNTED REMOTE CONTROL

This fireplace features a two-button wall switch assembly with glowing LED’s. The wall switch performs the same functions as the wireless hand-held remote control with the added feature of LED’s for visual feedback of operation and status.

BLOWER ASSEMBLY

This fireplace includes a blower assembly. The blower operates thermostatically. The blower circulates heated air from the fireplace into the room.

For..com

110112-01A

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesLocal Codes Product FeaturesUnpacking AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Ventilation AIRDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingCheck GAS Type InstallationVentilation Air From Outdoors Installation Clearances Installation SequenceRemoving Fireplace Screen and Floor Assembly Electrical HookupRelocating Wall Switch Assembly Electrical Connections for Power CordRelocating Wall Switch Assembly Installing GAS Piping to Fireplace Location Mounting Wall Switch Assembly to Side of MantelConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Conventional Fireplace Installation HoleBUILT-IN Fireplace Installation Mantel Clearances for Built-In InstallationInstalling Logs Installing HoodAssembling and Attaching Optional Brass Trim Installing Battery Into Remote Installing Log #2 Right and Log #3 LeftInstalling Screen For Your Safety Read Before LightingUsing Supplied Wall Switch Assembly Operating FireplaceTo Turn OFF GAS To Appliance For Electrical Power OutageManual Lighting Instructions Shutting Off Heater When Manually Lit Inspecting BurnersOptional Blower Operation Operating FANCleaning Burner Injector Holders and Pilot AIR Inlet Holes Cleaning MaintenanceBurner Flame Patterns Specifications LogsTroubleshooting Observed Problem Possible Cause RemedyFor Com Gas leak. See Warning statement Illustrated Parts Breakdown Parts List Remote Control LOG Base Assembly Models VTGF33PRA VTGF33NRAFireplace Models VTGF33NRA VTGF33PRA Fireplace Models VTGF33NRA and VTGF33PRA Accessories Cleaning KIT GCK Slim Hearth BaseLaminate Trim for Hearth or Mantel Firebox Brick Liner G8000 SeriesReplacement Parts Service HintsTechnical Service Wiring DiagramTemplates Diameter HolesThis page Intentionally Left Blank Owners Registration Form Postage Required 110112-01A Not a UPC