OPERATING FIREPLACE
Normal Lighting Instructions
To Turn Off Gas To Appliance Manual Lighting Instructions for Electrical Power Outage
19
OPERATING FIREPLACE
Continued
4.To lower flame, push HI/LO button on wall switch once. Note: This fireplace does not have a
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
5.To lower flame, point remote control toward lower front of fireplace and push HI/LO button once.
Note: This fireplace does not have a
TO TURN OFF GAS
TO APPLIANCE
HI/LO |
Button |
LED |
Figure 37 - Control Locations
ON/OFF Button
Wall Switch
Assembly
Manual Ignition Bypass Switch (Up is for Remote Control)
Shutting Off Heater - Wall Switch
Push ON/OFF button on wall switch once.
Shutting Off Heater - Wireless Remote Control
Point remote control toward lower front of fireplace and push both buttons at the same time.
MANUAL LIGHTING INSTRUCTIONS
Thermocouple |
| |
| Manual | |
Automatic | Ignitor | |
Electrode | ||
Ignitor | ||
Electrode | Pilot | |
| Burner | |
Figure 38 - Pilot (Propane/LP Gas Shown) |
|
B. Using Hand-Held Wireless Remote Control
1. Set manual ignition bypass switch on control panel to OFF |
position (automatic ignition position). |
2. Wait five (5) minutes to clear out any gas. Smell for gas |
around heater and near floor. If you smell gas, STOP! Fol- |
low “B” in the safety information on warnings plate. If you |
don’t smell gas, go to the next step. |
3. Point remote control toward the lower front of fireplace |
and push both buttons at the same time. Hold for 6 sec- |
onds. The gas valve will open and electronic ignition will |
begin sparking to light the pilot. Note: You will be able to |
hear a clicking sound during this process. LED on wall |
switch will light. |
Note: You may be running this heater for the first time |
after connecting to gas supply or at the start of your heat- |
ing season. If so, the ON button may need to be pressed |
again. This will allow air to bleed from gas system. If sev- |
eral attempts to light pilot fail, contact a qualified service |
person or gas supplier for repairs. Until repairs are made, |
FOR ELECTRICAL POWER OUTAGE
WARNING: You must operate this heater with the fireplace screen in place. Make sure fireplace screen is in place before running heater.
NOTICE: During initial operation of new heater, burning logs will give off a
Because this fireplace has an electronic ignition system, in the event there is a loss of power, it will be necessary to manually light the pilot with the piezo ignitor. After the pilot is lit, the main burner will light automatically.
1.Follow steps 1 through 3 under Normal Lighting Instructions, pages 18 and 19.
2.Set manual ignition bypass switch on control panel to ON position (manual ignition position). See Figure 39.
3.The pilot is attached to the rear of the front burner. You will be able to see the pilot and spark electrode without removing the screen or logs.
HI/LO | ON/OFF | LED |
LED Button | Manual Ignition | |
Button |
| |
|
| Bypass Switch |
|
| (Down is ON) |
light and operate manually (see Manual Lighting Instruc- |
tions for Electrical Power Outage). |
4. When pilot flame is lit, the thermocouple is heated by the |
flame. When thermocouple becomes hot (5 to 15 seconds), |
main burner will automatically light on high flame. |
Wall
Switch Piezo
Ignitor
Figure 39 - Control Locations
Gas
Valve
Magnetic Manual
Override Handle
For morevisit www..com