Desa VTGF33NRA Inspecting Burners, Optional Blower Operation, Operating FAN, Pilot Flame Pattern

Page 20

20

OPERATING FIREPLACE

Manual Lighting Instructions for Electrical Power Outage (Cont.) To Turn Off Gas To Appliance

Optional Blower Operation

INSPECTING BURNERS

Pilot Flame Pattern

OPERATING FIREPLACE

Continued

4.Place the magnetic manual override handle, provided with this unit, on the end of the gas valve stem (see Figure 39, page 19).

5.Turn the override handle fully counterclockwise to the PILOT position. The handle will not stop but will begin to slip when you have fully turned to the PILOT position.

6.While holding the valve handle in the PILOT position, press and release piezo ignitor button (see Figure 39, page 19). This will light the pilot. If needed, keep pressing ignitor button until pilot lights.

7.When pilot flame is lit, hold manual override handle until thermocouple heats (approximately 5 to 15 seconds). If pi- lot goes out, repeat process. If several attempts to light the pilot fail, contact a qualified service person or gas supplier for repairs.

8.When thermocouple is heated, release override handle. The main burner will immediately light on high flame. Adjust flame size by turning override handle.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater When Manually Lit

Set manual ignition bypass switch on control panel to OFF (automatic ignition position). This will cause the controls to shut down the fireplace.

OPTIONAL BLOWER

OPERATION

Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Follow installation instructions included with the blower accessory.

OPERATING

FAN

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient in- crease in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Piezo Ignitor

AUTO/OFF/ON

Switch

Fan Switch

Figure 40 - AUTO/OFF/ON Switch

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 41 on page 21 shows a correct pilot flame pattern. Figure 42, page 21, shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermo- couple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 42, page 21

turn heater off (see To Turn Off Gas to Appliance, page 19 or col- umn 1)

see Troubleshooting, pages 23 through 25

Note: The pilot flame on natural gas units will have a slight curve, but the flame should be blue and have no yellow or orange color.

For..com

110112-01A

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesUnpacking Product FeaturesLocal Codes AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Ventilation AIRDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside BuildingVentilation Air From Outdoors InstallationCheck GAS Type Installation Clearances Installation SequenceRemoving Fireplace Screen and Floor Assembly Electrical HookupRelocating Wall Switch Assembly Electrical Connections for Power CordRelocating Wall Switch Assembly Installing GAS Piping to Fireplace Location Mounting Wall Switch Assembly to Side of MantelConnecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsPressure Testing Gas Supply Piping System Conventional Fireplace Installation HoleBUILT-IN Fireplace Installation Mantel Clearances for Built-In InstallationAssembling and Attaching Optional Brass Trim Installing HoodInstalling Logs Installing Battery Into Remote Installing Log #2 Right and Log #3 LeftInstalling Screen For Your Safety Read Before LightingUsing Supplied Wall Switch Assembly Operating FireplaceManual Lighting Instructions For Electrical Power OutageTo Turn OFF GAS To Appliance Shutting Off Heater When Manually Lit Inspecting BurnersOptional Blower Operation Operating FANBurner Flame Patterns Cleaning MaintenanceCleaning Burner Injector Holders and Pilot AIR Inlet Holes Specifications LogsTroubleshooting Observed Problem Possible Cause RemedyFor Com Gas leak. See Warning statement Illustrated Parts Breakdown Parts List Remote Control LOG Base Assembly Models VTGF33PRA VTGF33NRAFireplace Models VTGF33NRA VTGF33PRA Fireplace Models VTGF33NRA and VTGF33PRA Accessories Cleaning KIT GCK Slim Hearth BaseLaminate Trim for Hearth or Mantel Firebox Brick Liner G8000 SeriesReplacement Parts Service HintsTechnical Service Wiring DiagramTemplates Diameter HolesThis page Intentionally Left Blank Owners Registration Form Postage Required 110112-01A Not a UPC