![](/images/new-backgrounds/1325723/32572325x1.webp)
INSTALLATION
Continued
Installing 9-Volt Battery in Hand-Held Remote Control Unit
1.Remove battery cover on back of remote control unit.
2.Attach terminal wires to the battery (not in- cluded). Place battery into the battery housing. Note: Only use alkaline battery.
3.Replace battery cover onto remote control unit.
Battery Cover | Remote | |
Control Unit | ||
|
Terminal
Wires
Battery
Housing
Battery
Figure 17 - Installing Battery in Hand-
Held Remote Control Unit
GAS LINE HOOK-UP
WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.
WARNING: Before you pro- ceed, make sure your gas supply is OFF.
A manual shutoff valve has been included in the applianceʼs gas supply system. You may consider installing an extra gas shutoff valve outside the applianceʼs enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 18.
In conformance with local codes, route a 1/2" NPT gas line to the appliance through hole in left side of firebox or
CAUTION: Do not kink flex- ible gas line.
DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 20) and into the appliance. Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 21, page 14).
Before connecting the black iron gas line to the inside of the appliance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with
local building codes). |
| |
Key | Shutoff | |
Valve | ||
|
|
|
|
|
|
|
| Extension |
Typical Exterior Wall Gas |
|
| |||||
Shutoff Installation |
|
|
| ||||
| Figure 18 - Manual Shutoff Valve | ||||||
|
|
|
| Installation |
|
| |
1/2" NPT Incoming |
|
|
|
| |||
Black Iron Gas Line |
|
|
|
| |||
| A |
|
| 7" |
|
| |
|
|
|
|
|
| ||
|
|
|
| 7" | Alternate Gas Supply | ||
|
|
|
|
| |||
|
|
|
|
| Through | ||
|
| M36(B,H), |
| M42(B,H), | |||
|
| M36P(B,H |
| M42P(B,H) | |||
|
| VM36(B,H), | VM42(B,H), | ||||
A | VM36P(B,H) | VM42P(B,H) | |||||
8 | 5 | /8" | (219 mm) | 10 | 1 | /2" (267 mm) | |
Figure 19 - Routing Incoming Gas Line | |||||||
|
|
|
|
|
|
| Incoming |
|
|
|
|
|
|
| 1/2" Gas Line |
|
|
|
|
|
|
| Permitted by |
Sediment |
|
|
|
| Local Codes | ||
Trap (Not |
|
|
|
|
| ||
Supplied) |
| 3" Min. |
|
|
| ||
|
|
|
|
|
|
| |
|
|
|
| (76mm) |
|
|
|
| Figure 20 - Sediment Trap |
www.desatech.com | 13 |