Desa VM42P installation manual Natural GAS, Propane/Lp Gas

Page 1

B-VENT DECORATIVE GAS FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

MODELS M36(B,H), M42(B,H), VM36(B,H) AND VM42(B,H)

NATURAL GAS

MODELS M36P(B,H), M42P(B,H), VM36P(B,H) AND VM42P(B,H)

PROPANE/LP GAS

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS :

Do not try to light any appliance.

Do not touch any electrical switch;

Do not use any phone in your building.

Immediatelycallyourgassupplierfromaneighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency or the gas supplier.

Save this manual for future reference.

For more information, visit www.desatech.com

Image 1
Contents PROPANE/LP GAS Natural GASTable of Contents High traffic areas Windy or drafty areas Safety InformationIntroduction UnpackingBefore YOU Begin Modification of the appliance or any of the componentsSelecting Location Possible Locations for Installing ApplianceM42B,H, VM42B,H Product Specifications10.5 in. WC 2.66 kPa Orifice SizeClearances PRE-INSTALLATION PreparationMantel Clearances and Wall DetailsFraming Rough Opening for Installing WallInstalling Transition Pipe and Starter Collar Venting Installationflue connection must be made using listed Vent Piping Starter Collar Transition Pipe Vent CollarRoof Pitch Typical B-Vent ConfigurationWall Switch Installation InstallationChecking for Proper Venting Installing Receiver Optional Wireless HAND-HELD Remote Control InstallationVolt Battery Clip Terminal Wires Receiver Receiver Plastic Mounting Clips Mounting BracketGAS Line HOOK-UP Installing 9-Volt Battery in Hand-Held Remote Control UnitM36PB,H M42PB,H Ember and PAN Material Placement Grate Pan and Ember Material Burner Pan LOG Placement for M36, M36P, VM36 and VM36P ModelsLog Notch Log 3 Log Notches LogNotch Log Log 2A Log 2B LOG Placement for M42, M42P, VM42 and VM42P ModelsLog Notches Log Notch Log 2BCombustion AIR KIT Model AK4 Optional Installing Optional Glass Door AccessoryAppliance Enclosure Spring Opening Vent DamperClip Screw Side Front Partially Opened DoorOperating Fireplace For Your Safety Read Before LightingLighting Instructions Inspecting Burners Pilot AssemblyTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationBurner Flame Pattern Cleaning MaintenancePilot and Burner LogsService Hints Wiring DiagramTechnical Service Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingElectrode at pilot spark at Connected, replace ignitorIf pilot lights, an improper Gas/air mixture causedGas leak. See Warning Models Illustrated Parts BreakdownDescription QTY Parts ListM36B,H, M36PB,H, VM36B,H and VM36PB,H Brick Liners for ModelsLogsets for Models M42B,H, M42PB,H, VM42B,H and VM42PB,H Accessories Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Firebox