Desa VM42P installation manual Ember and PAN Material Placement

Page 14

INSTALLATION

Continued

CAUTION: Compounds used on threaded joints of gas piping shall be resistant to the action of Liquefied Petroleum (LP or propane) and should be applied lightly to ensure excess sealant does not enter the gas line.

WARNING: All gas piping and connections must be tested for leaks after the installation is completed.

After ensuring that the gas valve is on, apply a commercial leak detection solution to all con- nections and joints. If bubbles appear, leaks can be detected and corrected.

Do not use an open flame for leak testing and do not operate any appliance if a leak is detected.

Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVER- TIGHTEN.

EMBER AND PAN MATERIAL PLACEMENT

1.Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 22).

2.Smooth the pan material just even with edges of the burner pan.

3.Remove the ember material from the bag and flatten small amounts into quarter size pieces and lay on top of the surface of the pan mate- rial (see Figure 23).

4.Place just enough to cover the entire surface and leave about a 1/2 inch gap under the lower grate members to allow air to flow (see Figure 24, page 15).

Grate

Vermiculite

Burner Pan

 

(Pan Material)

 

Figure 22 - Fill Entire Burner Pan with

 

Vermiculite

Ember Material

Vermiculite (Pan Material)

Grate

Burner

Pan

 

Figure 23 - Ember Material on Surface of Pan Material (Vermiculite)

Flexible Gas Line

Gas Shutoff Do NOT Kink

Valve

Note:

1) Wire Connections

Red Surface Indicates For Propane/LP Use Only

ON

T

O

L

I

P

OFF

IN OUT

Pilot Adj

1/2" NPT

Not Shown for Clarity

Incoming

2) * 1/8" NPT Plugged

Gas Line

Tapping

Outlet

Pressure Tap

Inlet Pressure Tap

Figure 21 - Connecting Flexible Gas Line to Millivolt Valve

14

www.desatech.com

108795-01N

Image 14
Contents Natural GAS PROPANE/LP GASTable of Contents Safety Information High traffic areas Windy or drafty areasBefore YOU Begin UnpackingIntroduction Modification of the appliance or any of the componentsPossible Locations for Installing Appliance Selecting Location10.5 in. WC 2.66 kPa Product SpecificationsM42B,H, VM42B,H Orifice SizeMantel Clearances and Wall PRE-INSTALLATION PreparationClearances DetailsRough Opening for Installing Wall Framingflue connection must be made using listed Venting InstallationInstalling Transition Pipe and Starter Collar Vent Piping Starter Collar Transition Pipe Vent CollarTypical B-Vent Configuration Roof PitchChecking for Proper Venting InstallationWall Switch Installation Volt Battery Clip Terminal Wires Receiver Optional Wireless HAND-HELD Remote Control InstallationInstalling Receiver Receiver Plastic Mounting Clips Mounting BracketM36PB,H M42PB,H Installing 9-Volt Battery in Hand-Held Remote Control UnitGAS Line HOOK-UP Ember and PAN Material Placement Log Notch Log 3 Log Notches LOG Placement for M36, M36P, VM36 and VM36P ModelsGrate Pan and Ember Material Burner Pan LogLog Notches LOG Placement for M42, M42P, VM42 and VM42P ModelsNotch Log Log 2A Log 2B Log Notch Log 2BAppliance Enclosure Installing Optional Glass Door AccessoryCombustion AIR KIT Model AK4 Optional Clip Screw Side Front Opening Vent DamperSpring Partially Opened DoorLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Pilot AssemblyInspecting Burners Optional HAND-HELD Remote OperationPilot and Burner Cleaning MaintenanceBurner Flame Pattern LogsTechnical Service Wiring DiagramService Hints Replacement PartsTroubleshooting Observed Problem Possible Cause RemedyIf pilot lights, an improper Connected, replace ignitorElectrode at pilot spark at Gas/air mixture causedGas leak. See Warning Illustrated Parts Breakdown ModelsParts List Description QTYBrick Liners for Models M36B,H, M36PB,H, VM36B,H and VM36PB,HLogsets for Models M42B,H, M42PB,H, VM42B,H and VM42PB,H Accessories Limited Warranty VENT-FREE Firebox Warranty InformationKeep this Warranty