INSTALLATION
Continued
OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION
Note: If using optional wireless
Installing Receiver
1.Remove the front refractory access panel by lifting up and angling out of the firebox opening (see Figure 13, page 11) to expose controls.
2.Disconnect wall switch wires from TH and TH/TP terminals on control valve (see Figure 14).
3.Install remote receiver unit onto mounting bracket using the two plastic mounting clips (see Figure 15).
4.Connect wires to control circuit. Connect white wire to terminal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety cir- cuit wiring (see Wiring Diagram, page 22).
5.Locate the battery clip mounted on the back of the receiver (see Figure 16).
6.Slide
7.Attach the terminal wires to the battery (see Figure 16).
8.Replace refractory brick access panel.
Receiver
Plastic
Mounting
Clips
Mounting Bracket
Figure 15 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)
9-Volt Battery
Battery
Clip
Terminal
Wires
Receiver
Figure 16 - Installing Battery in Receiver
To Safety Circuit | Route Millivolt | Wall Switch | |
Wires (Supplied) | (Supplied) | ||
| |||
| Through Gas Line |
| |
| Conduit Sleeve |
| |
| To Thermopile |
|
|
|
| ON |
IN | LO | T |
|
| TH | ||
P | |||
| I |
|
|
|
|
| FFO |
|
|
| TP |
|
|
| THTP |
| IN |
| OUT |
Note: If any of the original wire as supplied must be replaced, use 18 AWG TYPE CL2 (UL) 105 C (25 ft. length MAXIMUM) or equivalent.
Figure 14 - Wall Switch Wiring Diagram
(Back View
12 | www.desatech.com |