Desa VM42P Optional Wireless HAND-HELD Remote Control Installation, Installing Receiver

Page 12

INSTALLATION

Continued

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION

Note: If using optional wireless hand-held remote control, the wall switch is no longer operational.

Installing Receiver

1.Remove the front refractory access panel by lifting up and angling out of the firebox opening (see Figure 13, page 11) to expose controls.

2.Disconnect wall switch wires from TH and TH/TP terminals on control valve (see Figure 14).

3.Install remote receiver unit onto mounting bracket using the two plastic mounting clips (see Figure 15).

4.Connect wires to control circuit. Connect white wire to terminal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety cir- cuit wiring (see Wiring Diagram, page 22).

5.Locate the battery clip mounted on the back of the receiver (see Figure 16).

6.Slide 9-volt battery (not included) through the clip. Note: Only use alkaline battery.

7.Attach the terminal wires to the battery (see Figure 16).

8.Replace refractory brick access panel.

Receiver

Plastic

Mounting

Clips

Mounting Bracket

Figure 15 - Installing Remote Receiver (Shown from Rear of Mounting Bracket)

9-Volt Battery

Battery

Clip

Terminal

Wires

Receiver

Figure 16 - Installing Battery in Receiver

To Safety Circuit

Route Millivolt

Wall Switch

Wires (Supplied)

(Supplied)

 

 

Through Gas Line

 

 

Conduit Sleeve

 

 

To Thermopile

 

 

 

 

ON

IN

LO

T

 

 

TH

P

 

I

 

 

 

 

 

FFO

 

 

 

TP

 

 

 

THTP

 

IN

 

OUT

Note: If any of the original wire as supplied must be replaced, use 18 AWG TYPE CL2 (UL) 105 C (25 ft. length MAXIMUM) or equivalent.

Figure 14 - Wall Switch Wiring Diagram

(Back View

12

www.desatech.com

108795-01N

Image 12
Contents Natural GAS PROPANE/LP GASTable of Contents Safety Information High traffic areas Windy or drafty areasUnpacking IntroductionBefore YOU Begin Modification of the appliance or any of the componentsPossible Locations for Installing Appliance Selecting LocationProduct Specifications M42B,H, VM42B,H10.5 in. WC 2.66 kPa Orifice SizePRE-INSTALLATION Preparation ClearancesMantel Clearances and Wall DetailsRough Opening for Installing Wall FramingVenting Installation Installing Transition Pipe and Starter Collarflue connection must be made using listed Vent Piping Starter Collar Transition Pipe Vent CollarTypical B-Vent Configuration Roof PitchInstallation Wall Switch InstallationChecking for Proper Venting Optional Wireless HAND-HELD Remote Control Installation Installing ReceiverVolt Battery Clip Terminal Wires Receiver Receiver Plastic Mounting Clips Mounting BracketInstalling 9-Volt Battery in Hand-Held Remote Control Unit GAS Line HOOK-UPM36PB,H M42PB,H Ember and PAN Material Placement LOG Placement for M36, M36P, VM36 and VM36P Models Grate Pan and Ember Material Burner PanLog Notch Log 3 Log Notches LogLOG Placement for M42, M42P, VM42 and VM42P Models Notch Log Log 2A Log 2BLog Notches Log Notch Log 2BInstalling Optional Glass Door Accessory Combustion AIR KIT Model AK4 OptionalAppliance Enclosure Opening Vent Damper SpringClip Screw Side Front Partially Opened DoorFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Pilot Assembly Inspecting BurnersTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationCleaning Maintenance Burner Flame PatternPilot and Burner LogsWiring Diagram Service HintsTechnical Service Replacement PartsTroubleshooting Observed Problem Possible Cause RemedyConnected, replace ignitor Electrode at pilot spark atIf pilot lights, an improper Gas/air mixture causedGas leak. See Warning Illustrated Parts Breakdown ModelsParts List Description QTYBrick Liners for Models M36B,H, M36PB,H, VM36B,H and VM36PB,HLogsets for Models M42B,H, M42PB,H, VM42B,H and VM42PB,H Accessories Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Firebox