21
8.If “growing” bubbles appear on any of the connection points, you have detected a gas leak. Immediately close the LP Gas Cylinder valve by turning handle clockwise
a.If leak appears at either end of hose and regulator assembly, retighten the connection at the leak, but do not
b.If the leak is coming from the Gas Cylinder, from the valves at the Control Knobs, or if the leak cannot be stopped, do not use the grill. Call Customer Service at
9.Upon completion of leak test, turn all Control Knobs to the “Off” position. Turn the handle on the LP Gas Cylinder clockwise until it stops. Disconnect LP Gas Cylinder by turning coupling nut on regulator in a counterclockwise direction until regulator is released from threaded LP Gas Cylinder nozzle.
10.Place the protective cap over LP Gas Cylinder nozzle.
11.
Lighting the Grill Using the Pulse-Spark Ignitor
!WARNING
To reduce the risk of death or serious injury from an explosion or a fire beneath the grill:
•Inspect and clean Burner/Venturi Tubes for insects or insect nests. Spiders or small insects can build nests, webs, and lay eggs in the grill’s Venturi Tubes, (Fig 15 - page 31) obstructing the flow of gas to the Burner. The
•Be sure Burners are
Should you notice that your Burner(s) are getting hard to light or the flame is not as hot as it once was, refer to the “How to Clean your Burners” section on page 31, to remove any possible obstructions.