WARNING
FILLING THE LP GAS CYLINDER:
•Allow only qualified LP gas dealers to properly fill or repair your LP gas cylinder.
•New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank.
•DO NOT allow the cylinder to be filled beyond 80% capacity.
•Always use a protective cylinder cap when grill is not connected to cylinder.
•If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1 valve and an
INSTALLING THE LP GAS CYLINDER ONTO THE GRILL: |
| |
1. | Check that the cylinder valve is closed by turning the knob |
|
| clockwise. |
|
2. | Place the cylinder into the tank holder in the bottom |
|
| of cabinet. |
|
3. | Orient the cylinder such that the valve opening faces the |
|
| side table, and so that the hose is not kinked or damaged. |
|
4. | Fully tighten the cylinder clamp underneath tank holder to |
|
| secure tank. | Tank Holder |
5.Attach or detach regulator to the LP gas cylinder only when cylinder is at rest in tank holder.
HOSE AND REGULATOR:
Your grill is equipped with a Type 1 connection device with the following features:
1.The system will not allow gas flow from the cylinder until a positive connection to the valve has been made.
Note: The cylinder valve must be turned off before any |
|
connection is made or removed. | Cylinder Clamp |
2.A thermal device that will shut off the gas flow if the device is subject to temperatures above 240°F to 300°F (115°C to 150°C). If this should happen, remove the entire regulator assembly and dispose of properly. A replacement regulator
assembly can be purchased by contacting customer service at
3. A regulator flow limiting device, when activated, restricts the flow of gas to 10 cubic feet per hour. If the flow limiting device is activated, perform Regulator Resetting Procedure .
REGULATOR RESETTING PROCEDURE
1.Turn burner control knobs to "OFF", turn off the cylinder valve and disconnect regulator from LP gas tank. Wait approximately two minutes.
2.Reattach regulator and slowly turn cylinder valve back on. The flow limiting device will now be reset.
6