Introduction

 

 

 

Data Entry Keys: Two pushbutton membrane switches are used to manually change measurement parameters of the instrument as they are displayed on the LED meter readout:

ƒUp Arrow Increment values of parameters upwards as they are displayed on the LED readout.

Down Arrow Increment values of parameters downwards as they are displayed on the LED readout.

Digital LED Readout: The digital display is a LED device that produces large, bright, 7-segment numbers that are legible in any lighting environment. It has two functions:

Meter Readout

As the meter readout, it displays the oxygen concentration currently being measured.

Measurement Parameters Readout

It also displays user-definable alarm set- points, ranges, and span calibration point when they are being checked or changed.

1.4 Rear Panel Description

The rear panel contains the electrical input and output connectors. Separate rear panel illustrations are shown in Figure 1-2 for the AC and DC powered versions of the instrument. The connectors are described briefly here and in detail in the Chapter 3 - Installation.

Teledyne Analytical Instruments

3

Image 11
Contents Teledyne Analytical Instruments Trace Oxygen AnalyzerCopyright 2009 Teledyne Instruments/ Analytical Instruments Model 3190ZSafety Messages Model 3190Z Table of Contents Maintenance Combustible GAS Usage Viii Trace Oxygen Analyzer Introduction Main Features of the AnalyzerIntroduction OverviewSpan Front Panel DescriptionIntroduction Model 3190Z Measurement Parameters Readout Rear Panel DescriptionMeter Readout Rear Panel AC and DC versions ƒ Power ConnectionAlarm Page Trace Oxygen Analyzer Operational Theory Operational TheoryIntroduction Zirconium Oxide SensorsGeneral ElectronicsOperational Theory Model 3190Z Effect of PressureBlock Diagram of the Signal Processing Electronics Signal ProcessingOperational Theory Model 3190Z Unpacking the Analyzer InstallationTrace Oxygen Analyzer Installation Location and Mounting Installation Model 3190ZControl Unit Installation External Probe InstallationPower switch is located below the fuse receptacle Rear Panel Electrical Connectors for AC and DC Units Contact ID for Failsafe Relay Operation Gas Connections Installation ChecklistTrace Oxygen Analyzer Operation OperationOperation Model 3190Z Using the Function and Data Entry ButtonsSetting the Analysis Ranges HI Range Setting the Alarm SetpointsHI Alarm LO AlarmCalibration Sensor Fail AlarmProcedure Selecting a Fixed Range or AutorangingLED Display on StartUp Page Replacing the Fuse MaintenanceTrace Oxygen Analyzer Maintenance AC Powered UnitsWhen to Replace a Sensor Sensor Installation or ReplacementMaintenance Model 3190Z DC Powered UnitsRange ID 0-10 VDC SpecificationsAppendix Trace Oxygen Analyzer AppendixAppendix Model 3190Z Spare Parts ListMiscellaneous Drawing List