Teledyne operating instructions Spare Parts List, Appendix Model 3190Z

Page 34

Appendix

Model 3190Z

 

 

 

A.2 Spare Parts List

1*

C-64586A

PC Board, Power Supply (AC-version)

1*

C-64586B

PC Board, Power Supply (DC-version)

1

C-76491C

PCB Board, Main

1

C-76490C

Interface Unit

2*

F-1130

Fuse (AC), ½A, 250 VAC

 

 

IEC Type T, 5x20mm

1*

F-51

Fuse (DC), ½A, 125 VDC Micro-fuse

1

S-1439

Sensor, 0-1,000 ppm, zirconium oxide

* - configuration-dependent

 

A minimum charge of US $150.00 is applicable to spare parts orders.

IMPORTANT: Orders for replacement parts should include the part number and the model and serial number of the system for which the parts are intended.

Send orders to:

TELEDYNE ELECTRONIC TECHNOLOGIES

Analytical Instruments

16830 Chestnut Street

City of Industry, CA 91749-1580

Telephone: (626) 961-9221

TWX: (910) 584-1887 TDYANYL COID

Fax: (626) 961-2538

…or your local representative.

Teledyne Analytical Instruments

26

Image 34
Contents Trace Oxygen Analyzer Teledyne Analytical InstrumentsModel 3190Z Copyright 2009 Teledyne Instruments/ Analytical InstrumentsSafety Messages Model 3190Z Table of Contents Maintenance Combustible GAS Usage Viii Overview Main Features of the AnalyzerIntroduction Trace Oxygen Analyzer IntroductionIntroduction Model 3190Z Front Panel DescriptionSpan Meter Readout Rear Panel DescriptionMeasurement Parameters Readout ƒ Power Connection Rear Panel AC and DC versionsAlarm Page Zirconium Oxide Sensors Operational TheoryIntroduction Trace Oxygen Analyzer Operational TheoryEffect of Pressure ElectronicsOperational Theory Model 3190Z GeneralSignal Processing Block Diagram of the Signal Processing ElectronicsOperational Theory Model 3190Z Trace Oxygen Analyzer Installation InstallationUnpacking the Analyzer External Probe Installation Installation Model 3190ZControl Unit Installation Location and MountingPower switch is located below the fuse receptacle Rear Panel Electrical Connectors for AC and DC Units Contact ID for Failsafe Relay Operation Installation Checklist Gas ConnectionsOperation Trace Oxygen Analyzer OperationSetting the Analysis Ranges Using the Function and Data Entry ButtonsOperation Model 3190Z LO Alarm Setting the Alarm SetpointsHI Alarm HI RangeSelecting a Fixed Range or Autoranging Sensor Fail AlarmProcedure CalibrationLED Display on StartUp Page AC Powered Units MaintenanceTrace Oxygen Analyzer Maintenance Replacing the FuseDC Powered Units Sensor Installation or ReplacementMaintenance Model 3190Z When to Replace a SensorTrace Oxygen Analyzer Appendix SpecificationsAppendix Range ID 0-10 VDCSpare Parts List Appendix Model 3190ZDrawing List Miscellaneous